Experimental investigations of the scanning functions of galvanometer-based scanners with applications in OCT.

We analyze the three most common profiles of scanning functions for galvanometer-based scanners (GSs): the sawtooth, triangular and sinusoidal functions. They are determined experimentally with regard to the scan parameters of the input signal (i.e., frequency and amplitude). We study the differences of the output function of the GS measured as the positional error of the oscillatory mirror from the ideal function given by the input signal of the device. The limits in achieving the different types of scanning functions in terms of duty cycle and linearity are determined experimentally for the possible range of scan parameters. Of particular importance are the preservation of an imposed duty cycle and profile for the sawtooth function, the quantification of the linearity for the sinusoidal function, and the effective duty cycle for the triangular, as well as for the other functions. The range of scan amplitudes for which the stability of the oscillatory regime of the galvo mirror is stable for different frequencies is also highlighted. While the use of the device in certain scanning regimes is studied, certain rules of thumb are deduced to make the best out of the galvoscanner. Finally, the three types of scanning functions are tested with a Fourier domain optical coherence tomography (FD OCT) setup and the conclusions of the study are demonstrated in an imaging application by correlating the determined limits of the scanning regimes with the requirements of OCT.

[1]  S. Yun,et al.  115 kHz tuning repetition rate ultrahigh-speed wavelength-swept semiconductor laser. , 2005, Optics letters.

[2]  John Rogers,et al.  Fast scanning transmissive delay line for optical coherence tomography. , 2005, Optics letters.

[3]  J. S. Gadhok,et al.  Achieving high-duty cycle sawtooth scanning with galvanometric scanners , 1999, Optics & Photonics.

[4]  Michael N. Sweeney Polygon scanners revisited , 1997, Optics & Photonics.

[5]  Sean Coleman High capacity aerodynamic air bearing (HCAB) for laser scanning applications , 2005, SPIE Optics + Photonics.

[6]  Eric Clarkson,et al.  Dispersion control with a Fourier-domain optical delay line in a fiber-optic imaging interferometer. , 2005, Applied optics.

[7]  Richard B Rosen,et al.  Sequential optical coherence tomography and confocal imaging. , 2004, Optics letters.

[8]  Kevin Hsu,et al.  Dual detection full range frequency domain optical coherence tomography. , 2010, Optics letters.

[9]  K. Ohbayashi,et al.  Fourier domain optical coherence tomography using optical demultiplexers imaging at 60,000,000 lines/s. , 2008, Optics letters.

[10]  Jun Xie,et al.  Correction of the image distortion for laser galvanometric scanning system , 2005 .

[11]  Virgil-Florin Duma,et al.  Optimal scanning function of a galvanometer scanner for an increased duty cycle , 2010 .

[12]  S. Marcos,et al.  Optical distortion correction in optical coherence tomography for quantitative ocular anterior segment by three-dimensional imaging. , 2010, Optics express.

[13]  Hyungsuck Cho,et al.  Optical design of a variable view imaging system with the combination of a telecentric scanner and double wedge prisms. , 2010, Applied optics.

[14]  Daisuke Miyazaki,et al.  Volumetric display system based on three-dimensional scanning of inclined optical image. , 2006, Optics express.

[15]  Virgil-Florin Duma,et al.  Mathematical Functions of a 2-D Scanner with Oscillating Elements , 2009 .

[16]  P. So,et al.  High-speed, two-photon scanning microscope. , 1999, Applied optics.

[17]  Virgil-Florin Duma,et al.  Neutral density filters with Risley prisms: analysis and design. , 2009, Applied optics.

[18]  Leo Beiser,et al.  Fundamental architecture of optical scanning systems. , 1995, Applied optics.

[19]  Bruce E. Rohr Testing high-performance galvanometer-based optical scanners , 1995, Photonics West.

[20]  Redmond P. Aylward,et al.  Advances and technologies of galvanometer-based optical scanners , 1999, Optics & Photonics.

[21]  Adrian Gh. Podoleanu,et al.  Perspectives of optical scanning in OCT , 2010, BiOS.

[22]  Jannick P. Rolland,et al.  Broadband Fourier-domain mode-locked lasers , 2011 .

[23]  William C Warger,et al.  Dual-wedge scanning confocal reflectance microscope. , 2007, Optics letters.

[24]  Michael Pircher,et al.  Full range complex spectral domain optical coherence tomography without additional phase shifters. , 2007, Optics express.

[25]  Chenbo Xie,et al.  Characteristics of aerosol optical properties in pollution and Asian dust episodes over Beijing, China. , 2008, Applied optics.

[26]  Adrian Gh. Podoleanu,et al.  Combinations of techniques in imaging the retina with high resolution , 2008, Progress in Retinal and Eye Research.

[27]  M. Jenkins,et al.  In vivo gated 4D imaging of the embryonic heart using optical coherence tomography. , 2007, Journal of biomedical optics.

[28]  Jannick P. Rolland,et al.  Swept-source based, single-shot, multi-detectable velocity range Doppler optical coherence tomography , 2010, Biomedical optics express.

[29]  Wolfgang Wieser,et al.  Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second. , 2010, Optics express.

[30]  Maciej Wojtkowski,et al.  Scanning protocols dedicated to smart velocity ranging in spectral OCT. , 2009, Optics express.