Lengths measurements in microvascular corrosion castings: two-dimensional versus three-dimensional morphometry.

In the present study we compared measurements of vessel lengths from (a) single-digital scanning electron microscope (SEM) images of microvascular corrosion casts (VCCs) of gill filters of tadpoles of Xenopus laevis Daudin by two-dimensional (2-D) morphometry (Optimas 6.5, Optimas Corp., Bothell, Wash., USA; planar measurements) and (b) digital stereopairs by three-dimensional (3-D) morphometry (3D-Morphometry, Minnich and Muska OEG, Salzburg). Depending on the spatial orientation of the vessels measured, we found a maximum difference of 58.84% (100 [3-D]-41.16 [2-D]) in vessel lengths by 3-D morphometry versus 2-D morphometry, which, in multiple (segmental) lengths measurements or when determining space angles, might be even higher. Based on results we consider 3-D morphometry of VCCs to be the method of choice for lengths measurements.

[1]  D. Schraufnagel,et al.  Microvascular corrosion casting of the lung. A state-of-the-art review. , 1987, Scanning microscopy.

[2]  T Murakami,et al.  Application of the scanning electron microscope to the study of the fine distribution of the blood vessels. , 1971, Archivum histologicum Japonicum = Nihon soshikigaku kiroku.

[3]  S. Aharinejad,et al.  Microvascular Corrosion Casting in Scanning Electron Microscopy , 1992 .

[4]  Edward W. N. Bernroider,et al.  Three‐dimensional morphometry in scanning electron microscopy: a technique for accurate dimensional and angular measurements of microstructures using stereopaired digitized images and digital image analysis , 1999, Journal of microscopy.

[5]  Konerding Ma Scanning electron microscopy of corrosion casting in medicine. , 1991 .

[6]  M. R. Roach,et al.  Quantitative measurements of early atherosclerotic lesions on rabbit aortae from vascular casts. , 1989, Atherosclerosis.

[7]  A. Lametschwandtner,et al.  Technical parameters of plastics (Mercox CL-2B and various methylmethacrylates) used in scanning electron microscopy of vascular corrosion casts. , 1986, Scanning electron microscopy.

[8]  A. Lametschwandtner,et al.  Scanning electron microscopy of vascular corrosion casts--technique and applications: updated review. , 1990, Scanning microscopy.

[9]  M. Konerding,et al.  A simple and accurate method for 3-D measurements in microcorrosion casts illustrated with tumour vascularization. , 1995, Analytical cellular pathology : the journal of the European Society for Analytical Cellular Pathology.

[10]  M. Miyoshi,et al.  Measurement of geometrical dimensions using scanning electron microscopy , 1999 .

[11]  Kratky Rg,et al.  Scanning electron microscopy of early atherosclerosis in rabbits using aortic casts. , 1988, Scanning microscopy.

[12]  J. Gassner,et al.  Diluted and undiluted Mercox severely destroy unfixed endothelial cells. A light and electron microscopic study using cultured endothelial cells and tadpole tail fin vessels. , 1994, Scanning microscopy.

[13]  M. R. Roach,et al.  Endothelial cell morphometry near branch junctions of rabbit aortae. , 1987, Canadian journal of physiology and pharmacology.

[14]  A. Lametschwandtner,et al.  Vascular regression during amphibian metamorphosis--a scanning electron microscope study of vascular corrosion casts of the ventral velum in tadpoles of Xenopus laevis Daudin. , 2006, Scanning.

[15]  M. R. Roach,et al.  Quantitative measurement from vascular casts. , 1989, Scanning microscopy.

[16]  B. Nilsson,et al.  Microvascular corrosion casting with analysis in the scanning electron microscope , 1988 .