Long‐term results of 1 millimeter arterial anastomosis using the 3M precise microvascular anastomotic system

The 3M Precise Microvascular Anastomotic System has been tested experimentally in long‐term studies of arteries of 1 mm in diameter for the first time. The device was placed, using a newly described technique, in the infrarenal aorta of 25 rats. At different intervals (2 weeks, 16 weeks, and 1 year), the section containing the 3M Precise Microvascular Anastomotic System was removed and processed for light microscopy and scanning electron microscopy. All the anastomoses were found to be patent. Using a new device to process the material, both light microscopy and scanning electron microscopy at 2 weeks showed a perfect reparative process at the junction site and the presence of a continuous endothelial layer. Media atrophy was responsible for wall thinning within the device. At 16 weeks, the atrophy of the media was even more marked, reducing the vessel wall thickness within the device to one‐third of normal. At 1 year, this atrophy of the media was complete; smooth muscle cells disappeared and were replaced by fibrous tissue. Adventitia was not present over the long term within the device. The continuous endothelial layer, however, was still viable. These long‐term results suggest that scar tissue forms within the device, while a continuous endothelial layer remains viable internal to this. © Wiley‐Liss, Inc.

[1]  G. Nylander,et al.  The UNILINK system for mechanical microvascular anastomosis in hand surgery. , 1989, The Journal of hand surgery.

[2]  L. Östrup,et al.  Microvascular Anastomoses in Irradiated Vessels: A Comparison Between the Unilink System and Sutures , 1990, Plastic and reconstructive surgery.

[3]  L. Östrup,et al.  Strength of microvascular anastomoses: Comparison between the unilink anastomotic system and sutures , 1989, Microsurgery.

[4]  K. Nakayama,et al.  A simple new apparatus for small vessel anastomosisi (free autograft of the sigmoid included). , 1962, Surgery.

[5]  T. Brown,et al.  A microvascular anastomotic device: Part i. a hemodynamic evaluation in rabbit femoral arteries and veins , 1989, Microsurgery.

[6]  M. Rohman,et al.  Internal mammary-coronary artery anastomosis. A nonsuture method employing tantalum rings. , 1961, The Journal of thoracic and cardiovascular surgery.

[7]  R. Daniel,et al.  An Absorbable Anastomotic Device for Microvascular Surgery: Experimental Studies , 1984, Plastic and reconstructive surgery.

[8]  N. Tamaki,et al.  Nonsuture microvascular anastomosis using magnet rings: preliminary report. , 1978, Surgical neurology.

[9]  L. Ostrup,et al.  Microvenous grafts to arterial defects. The use of mechanical or suture anastomoses. , 1989, Archives of otolaryngology--head & neck surgery.

[10]  B. F. Matlaga,et al.  An Anastomotic Device for Microvascular Surgery: Evolution , 1984, Annals of plastic surgery.

[11]  L. Ostrup,et al.  Mechanical anastomosis of small arteries and veins with the unilink apparatus: a histologic and scanning electron microscopic study. , 1987, Plastic and reconstructive surgery.

[12]  C. Steyers,et al.  A microvascular anastomotic device: Part II. A Histologic Study In Arteries And Veins , 1989, Microsurgery.

[13]  L. Östrup,et al.  The UNILINK Instrument System for Fast and Safe Microvascular Anastomosis , 1986, Annals of plastic surgery.