Average permeability measurements for an individual dwelling in Romania

Abstract The air permeability represents that feature of the building playing a major role in both the building energy performance and the indoor environment quality, therefore its prediction is very important. The statistical prediction models which are used today on a very large scale present large errors. The experimental measurements correct this deficit, but they are impossible to be carried out for large apartment building due to technical concerns. In this study we propose an intermediate approach “the prediction of average permeability as a weighted mean of the different measured permeabilities characteristic to the different types of joinery”. The article presents the mathematical models and the adapted experimental protocol for four different parameters that describes the permeability. The experimental work was carried out for an apartment placed at the ground level of a two storey house in Romania. The proposed approach presents smaller errors: 5% for the overall leakage airflow and 15% for the average permeability. The study presents interesting data being among the first permeability measurements in Romania. The originality of the study is also given by the proposed model which is oriented towards large dimensions blocks of apartments.

[1]  De-Ling Liu,et al.  Modeling pollutant penetration across building envelopes , 2001 .

[2]  D. Michell,et al.  Air permeability of some Australian houses , 1986 .

[3]  Myoung-Souk Yeo,et al.  Characteristics of pressure distribution and solution to the problems caused by stack effect in high-rise residential buildings , 2007 .

[4]  Vlad Iordache Etude de l'impact de la pollution atmosphérique sur l'exposition des enfants en milieu scolaire : recherche de moyens de prédiction et de protection , 2003 .

[5]  Cheung,et al.  Changes in air leakage levels of six Canadian office buildings , 1993 .

[6]  C. Simonson Energy consumption and ventilation performance of a naturally ventilated ecological house in a cold climate , 2005 .

[7]  M. Sherman INFILTRATION-PRESSURIZATION CORRELATION: SIMPLIFIED PHYSICAL MODELING , 1980 .

[8]  M. N. Assimakopoulos,et al.  Air tightness measurements of residential houses in Athens, Greece , 2008 .

[9]  William S. Dols,et al.  CONTAMW 1.0 User Manual: Multizone Airflow and Contaminant Transport Analysis Software | NIST , 2000 .

[10]  Sivert Uvsløkk,et al.  The Importance of Wind Barriers for Insulated Timber Frame Constructions , 1996 .

[11]  Jean-Marie Fürbringer,et al.  The influence of the user on the results of multizone air flow simulations with COMIS , 1999 .

[12]  J. Bendat,et al.  Random Data: Analysis and Measurement Procedures , 1971 .

[13]  J. Reardon,et al.  Evaluation of the Alberta air infiltration model using measurements and inter-model comparisons , 2009 .

[14]  Michael D. Sohn,et al.  Analyzing a database of residential air leakage in the United States , 2005 .

[15]  Helmut E. Feustel COMIS—an international multizone air-flow and contaminant transport model , 1999 .

[16]  Eulàlia Planas,et al.  Air leakage in Catalan dwellings: Developing an airtightness model and leakage airflow predictions , 2010 .

[17]  Francis Allard,et al.  Multicriteria analysis of ventilation in summer period , 2002 .

[18]  Targo Kalamees,et al.  Building leakage, infiltration, and energy performance analyses for Finnish detached houses , 2009 .

[19]  D. Gross,et al.  Analysis And Prediction Of Air Leakage Through Door Assemblies , 1989 .

[20]  M. H. Sherman and W. R. Chan,et al.  Building Air Tightness: Research and Practice , 2006 .