Outcomes of proximal interphalangeal joint pyrocarbon implants.

PURPOSE To prospectively register and report the hand function and occupational performance of patients with proximal interphalangeal joint-pyrocarbon arthroplasty, using both objective tests and subjective outcome instruments. METHODS From 2004 to 2008, 53 joints in 43 patients were reconstructed with a proximal interphalangeal joint-pyrocarbon prosthesis. The patients underwent a rehabilitation program allowing early motion with an extension stop to limit hyperextension. Range of motion, grip strength, and pain (Visual Analog Scale [VAS]) were recorded and the subjective outcome was evaluated using Canadian Occupational Performance Measure (COPM) and Disabilities of the Arm, Shoulder, and Hand score. RESULTS Seven patients were reoperated on (2 infections, 2 arthrodesis, 2 tenolysis, and 1 hyperextension). Pain (VAS) at rest improved from 3.1 cm preoperatively to 0.4 cm (p < .001) and pain (VAS) at activity from 6.2 to 2.0 cm (p < .001) at the latest follow-up (mean, 24 months; minimum, 12 months [+/- 2 weeks]). Disabilities of the Arm, Shoulder, and Hand score improved from a median of 39 to 29 (p = .026). The COPM subjective measurement of occupational performance, improved from a median of 4.6 preoperatively to 5.9 (p = .013) at the latest follow-up, and the COPM, measurement of satisfaction improved from a median of 3.8 to 5.9 (p = .002). Range of motion and grip strength were unchanged. CONCLUSIONS All patients reported decreased pain, and although we found no improvement in range of motion and grip strength, one third of patients reported a clinically significant improvement in occupational performance and satisfaction. A total of 13% of the joints required a secondary surgical procedure. TYPE OF STUDY/LEVEL OF EVIDENCE Therapeutic IV.

[1]  C. Ekdahl,et al.  The disabilities of the arm, shoulder and hand (DASH) outcome questionnaire: longitudinal construct validity and measuring self-rated health change after surgery , 2003, BMC musculoskeletal disorders.

[2]  S D Cook,et al.  Long-term follow-up of pyrolytic carbon metacarpophalangeal implants. , 1999, The Journal of bone and joint surgery. American volume.

[3]  K. Pettersson,et al.  Replacement of proximal interphalangeal joints with new ceramic arthroplasty: A prospective series of 20 proximal interphalangeal joint replacements , 2006, Scandinavian journal of plastic and reconstructive surgery and hand surgery.

[4]  R. F. Sampaio,et al.  Work-related hand injuries: Case analyses in a Brazilian rehabilitation service , 2006, Disability and rehabilitation.

[5]  P. Stern,et al.  Pyrolytic carbon proximal interphalangeal joint resurfacing arthroplasty. , 2006, The Journal of hand surgery.

[7]  R. Beckenbaugh,et al.  Pyrolytic carbon proximal interphalangeal joint arthroplasty: results with minimum two-year follow-up evaluation. , 2007, The Journal of hand surgery.

[8]  Matthias Schulz,et al.  Der Fingermittelgelenkersatz mit Pyrocarbonprothesen , 2007, Operative Orthopädie und Traumatologie.

[9]  A. Sprinchorn,et al.  Self-administered outcome instrument in carpal tunnel syndrome. Reliability, validity and responsiveness evaluated in 102 patients. , 1998, Acta orthopaedica Scandinavica.

[10]  C. Goldfarb,et al.  Pyrolytic carbon arthroplasty for posttraumatic arthritis of the proximal interphalangeal joint. , 2006, The Journal of hand surgery.

[11]  C. Bombardier,et al.  Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand) [corrected]. The Upper Extremity Collaborative Group (UECG) , 1996, American journal of industrial medicine.

[12]  C. Carroll,et al.  Long-term Assessment of Swanson Implant Arthroplasty in the Proximal Interphalangeal Joint of the Hand , 2006 .

[13]  NeuFlex compared with Sutter prostheses: A blind, prospective, randomised comparison of Silastic metacarpophalangeal joint prostheses , 2006, Scandinavian journal of plastic and reconstructive surgery and hand surgery.

[14]  C. Bombardier,et al.  Development of an upper extremity outcome measure: The DASH (disabilities of the arm, shoulder, and head) , 1996 .

[15]  J Goldhahn,et al.  Problematic Bone Fixation with Pyrocarbon Implants in Proximal Interphalangeal Joint Replacement: Short-Term Results , 2006, Journal of hand surgery.