Assessment of Blood Coagulation Under Various Flow Conditions With Ultrasound Backscattering

Several in vitro studies have employed ultrasonic techniques to detect varying properties of coagulating blood under static or stirred conditions. Most of those studies mainly addressed on the development and feasibility of modalities and however were not fully considering the effect of blood flow. To better elucidate this issue, ultrasonic backscattering were measured from the coagulating porcine blood circulated in a mock flow loop with various steady laminar flows at mean shear rates from 10 to 100 s-1. A 3 ml of 0.5 M CaCl2 solution for inducing blood coagulation was added to that of 30 ml blood circulated in the conduit. For each measurement carried out with a 10-MHz transducer, backscattered signals digitized at 100-MHz sampling frequency were acquired for a total of 20 min at temporal resolution of 50 A-lines per s. The integrated backscatter (IB) was calculated for assessing backscattering properties of coagulating blood. The results show that blood coagulation tended to be increased corresponding to the addition of CaCl2 solution: the IB was increased approximately 6.1 plusmn 0.6 (mean plusmn standard deviation), 5.4 plusmn 0.9, and 4.5 plusmn 1.2 dB at 310 plusmn 62, 420 plusmn 88, and 610 plusmn 102 s associated with mean shear rates of 10, 40, and 100 s-1, respectively. The rate of increasing IB for evaluating the growth of clot was estimated to be 0.075 plusmn0.017,0.052 plusmn0.027, and 0.038 plusmn 0.012 DeltadB Deltas-1 corresponding to the increase of mean shear rates. These results consistently demonstrate that higher shear rate tends to prolong the duration for the flowing blood to be coagulated and to decrease the rate of IB. Moreover, the laminar flow was changed to turbulent flow during that the blood was clotting discerned by spatial variations of ultrasound backscattering in the conduit. All these results validate that ultrasound backscattering is feasible to be utilized for detecting and assessing blood coagulation under dynamic conditions.

[1]  Shyh-Hau Wang,et al.  Detecting the process of blood coagulation and clot formation with high frequency ultrasound , 2005 .

[2]  R. Sigelmann,et al.  Ultrasonic Measurement of Blood Coagulation Time , 1975, IEEE Transactions on Biomedical Engineering.

[3]  L A Crum,et al.  Color Doppler detection of acoustic streaming in a hematoma model. , 2001, Ultrasound in medicine & biology.

[5]  C. Hartley,et al.  Characteristics of acoustic streaming created and measured by pulsed Doppler ultrasound , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  F. Foster,et al.  Non-Gaussian statistics and temporal variations of the ultrasound signal backscattered by blood at frequencies between 10 and 58 MHz. , 2004, Journal of the Acoustical Society of America.

[7]  G. Cloutier,et al.  The effects of hematocrit, shear rate, and turbulence on ultrasonic Doppler spectrum from blood , 1992, IEEE Transactions on Biomedical Engineering.

[8]  G. Cloutier,et al.  Effect of the insonification angle on the Doppler backscattered power under red blood cell aggregation conditions , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  P. Tsui,et al.  Detection of blood coagulation and clot formation using quantitative ultrasonic parameters. , 2005, Ultrasound in medicine & biology.

[10]  Shyh-Hau Wang,et al.  In Vitro Study on Assessment of Blood Coagulation and Clot Formation Using Doppler Ultrasound , 2005 .

[11]  A Tippe,et al.  Shear dependence of the fibrin coagulation kinetics in vitro. , 1993, Thrombosis research.

[12]  L. Mazeika,et al.  Ultrasonic method for the whole blood coagulation analysis. , 2002, Ultrasonics.

[13]  D. Ku,et al.  Fluid mechanics of vascular systems, diseases, and thrombosis. , 1999, Annual review of biomedical engineering.

[14]  K. Shung,et al.  Ultrasonic backscatter from flowing whole blood. I: Dependence on shear rate and hematocrit. , 1988, The Journal of the Acoustical Society of America.

[15]  K. Shung,et al.  In vivo measurements of ultrasonic backscatter from blood , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[16]  J. Lai,et al.  A Viscometric Method to Study the Effects of Hematocrit of Blood and Different Surfaces of Biomaterials on Blood Clot Formation , 2000 .

[17]  D. Hett,et al.  Sonoclot analysis. , 1995, British journal of anaesthesia.

[18]  W. Reeves,et al.  Ultrasonic Characterization of Blood During Coagulation , 1984, Journal of clinical ultrasound : JCU.

[19]  J. S. Lee,et al.  A linear relation between the compressibility and density of blood. , 2001, The Journal of the Acoustical Society of America.

[20]  K. Shung,et al.  An approach for measuring ultrasonic backscattering from biological tissues with focused transducers , 1997, IEEE Transactions on Biomedical Engineering.

[21]  A. Malinka,et al.  Ultrasound spectroscopy applied to blood coagulation studies. , 1976, Ultrasonics.

[22]  Y. Nemerson,et al.  The Effect of Flow on Hemostasis and Thrombosis , 1991, Thrombosis and Haemostasis.

[23]  F. Dunn,et al.  Ultrasonic Scattering in Biological Tissues , 1992 .

[24]  H. Imamura,et al.  The effect of pulsatile shear flow on thrombus formation and hemolysis , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[25]  K. Shung,et al.  Ultrasonic backscatter from flowing whole blood. II: Dependence on frequency and fibrinogen concentration. , 1988, The Journal of the Acoustical Society of America.

[26]  Wade G. Holcomb,et al.  Principles of Applied Biomedical Instrumentation , 1969, The Yale Journal of Biology and Medicine.

[27]  J. C. Machado,et al.  Measurement of plasma clotting time using ultrasonic shear waves. , 1994, Physiological measurement.

[28]  G. Cloutier,et al.  Power Doppler ultrasound evaluation of the shear rate and shear stress dependences of red blood cell aggregation , 1996, IEEE Transactions on Biomedical Engineering.

[29]  Matthew O'Donnell,et al.  Broadband Integrated Backscatter: An Approach to Spatially Localized Tissue Characterization in Vivo , 1979 .

[30]  High frequency ultrasound characterization of the coagulation process of whole blood , 2004, IEEE Ultrasonics Symposium, 2004.

[31]  P. Grybauskas,et al.  Ultrasonic digital interferometer for investigation of blood clotting. , 1978, Ultrasonics.

[32]  Jf Davidson,et al.  Blood Coagulation and Haemostasis , 1980 .

[33]  K.K. Shung,et al.  In vivo measurements of ultrasonic backscattering in blood , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[34]  V T Turitto,et al.  Mechanical factors affecting hemostasis and thrombosis. , 1998, Thrombosis research.

[35]  S. Slack,et al.  The Effects of Flow on Blood Coagulation and Thrombosis , 1993, Thrombosis and Haemostasis.

[36]  P. Fitzgerald,et al.  The progression of thrombus in an ex-vivo shunt model evaluated by intravascular ultrasound radiofrequency analysis. , 1999, Ultrasound in medicine & biology.

[37]  P. Tsui,et al.  The effect of transducer characteristics on the estimation of Nakagami paramater as a function of scatterer concentration. , 2004, Ultrasound in medicine & biology.

[38]  J. Tarbell,et al.  Effect of flow disturbance on ultrasonic backscatter from blood. , 1984, The Journal of the Acoustical Society of America.