Oligocarbazoles as Ligands for Lead-selective Liquid Membrane Electrodes

Oligocarbazoles have been applied as new ionophores in liquid membrane electrodes (ISEs) destined for lead(II) determination in water samples. The oligocarbazole-containing ISEs demonstrated a close-to-Nernstian potentiometric response towards Pb^2+ in the activity range 10^-7 - 10^-2 M. The selectivity coefficients measured by the matched potential method (MPM) confirmed their good selectivity against common interfering mono- and doubly charged cations. The oligocarbazole-containing ISEs do not respond towards protons. Their applicability has been checked by performing the recovery test while using a sample of wastewater.

[1]  Y. Umezawa,et al.  Ion‐Selective Electrodes , 2005 .

[2]  A. Dybko,et al.  Towards advanced chemical microsensors-an overview. , 2004, Talanta.

[3]  A. Michalska,et al.  Conducting polymer membranes for low activity potentiometric ion sensing. , 2004, Talanta.

[4]  Philip A. Gale,et al.  Encyclopedia of Supramolecular Chemistry , 2004 .

[5]  Zbigniew Brzozka,et al.  Miniaturized sodium-selective sensors based on silicon back-side contact structure with novel self-plasticizing ion-selective membranes , 2003 .

[6]  Wim Dehaen,et al.  Synthesis of soluble oligocarbazole derivatives , 2003 .

[7]  A. Zaban,et al.  Electrochemical polymerization and characterization of a functional dicarbazole conducting polymer , 2003 .

[8]  A. Persoons,et al.  Photorefractive properties of bifunctional N-arylated carbazole derivatives in a carbazole polymer host matrix , 2002 .

[9]  B. Eggins Chemical Sensors and Biosensors , 2002 .

[10]  S. Cosnier,et al.  Mediated electrochemical detection of catechol by tyrosinase-based poly(dicarbazole) electrodes. , 2001, Journal of biochemical and biophysical methods.

[11]  H. Radecka,et al.  Methoxy-substituted derivatives of 1,4-bis(2-phenylethenyl)benzene and of 1,4-bis(2-phenylethyl)benzene as ligands in ion-selective electrodes for lead ions , 2001 .

[12]  M. Meyerhoff,et al.  Salicylate-selective membrane electrodes based on Sn(IV)- and OMo(V)-porphyrins: differences in response mechanism and analytical performance , 2001 .

[13]  M. Shibata,et al.  Studies on the Matched Potential Method for Determining the Selectivity Coefficients of Ion-Selective Electrodes Based on Neutral Ionophores: Experimental and Theoretical Verification , 2001, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[14]  E. Pretsch,et al.  Influence of key parameters on the lower detection limit and response function of solvent polymeric membrane ion-selective electrodes , 2001 .

[15]  M. Meyerhoff,et al.  Origin of non-Nernstian anion response slopes of metalloporphyrin-based liquid/polymer membrane electrodes. , 2000, Analytical chemistry.

[16]  S. Cosnier,et al.  Electrogenerated Poly(Chiral Dicarbazole) Films for the Reagentless Grafting of Enzymes , 2000 .

[17]  E. Malinowska,et al.  Macrocyclic Amides as Ionophores for Lead-Selective Membrane Electrodes , 2000 .

[18]  Yoshio Umezawa,et al.  Potentiometric Selectivity Coefficients of Ion-Selective Electrodes. Part I. Inorganic Cations (Technical Report) , 2000 .

[19]  D. Diamond,et al.  Lead-Selective Electrodes Based on Calixarene Phosphine Oxide Derivatives , 1999 .

[20]  W. Dehaen,et al.  Application of Thiacrown Ethers as Ligands for Lead-Selective Electrodes , 1999 .

[21]  Ernö Pretsch,et al.  Lowering the Detection Limit of Solvent Polymeric Ion-Selective Membrane Electrodes. 2. Influence of Composition of Sample and Internal Electrolyte Solution , 1999 .

[22]  Ernö Pretsch,et al.  Lowering the detection limit of solvent polymeric ion-selective electrodes. 1. Modeling the influence of steady-state ion fluxes , 1999 .

[23]  Ursula E. Spichiger-Keller,et al.  Chemical Sensors and Biosensors for Medical and Biological Applications , 1998 .

[24]  H. Radecka,et al.  Ion-Selective Liquid Membrane Electrode for Discrimination of Alkyllead Derivatives and Inorganic Lead Ions , 1998 .

[25]  E. Pretsch,et al.  Large Improvement of the Lower Detection Limit of Ion-Selective Polymer Membrane Electrodes , 1997 .

[26]  S. M. Zain,et al.  Electronic structures of carbazole and its derivatives: A semi-empirical study on the substitution effects of carbazole , 1997 .

[27]  D. B. Hibbert,et al.  Lead-selective membrane electrodes based on dithiophenediazacrown ether derivatives , 1997 .

[28]  Y. Umezawa,et al.  Selectivity coefficients for ion-selective electrodes: Recommended methods for reporting KA,Bpot values (Technical Report) , 1995 .

[29]  K. Cammann,et al.  PbOH+ -selective membrane electrode based on crown ethers , 1994 .

[30]  Satsuo Kamata,et al.  LEAD-SELECTIVE MEMBRANE ELECTRODE USING METHYLENE BIS(DIISOBUTYLDITHIOCARBAMATE) NEUTRAL CARRIER , 1991 .

[31]  S. Kamata,et al.  Methylene Bis(diisobutyldithiocarbamate) Neutral Carrier as Lead Sensing Material , 1991 .

[32]  W. E. Morf,et al.  Lead-selective neutral carrier based liquid membrane electrode , 1984 .