Ferromagnetic particles as a rapid and robust sample preparation for the absolute quantification of seven eicosanoids in human plasma by UHPLC-MS/MS.

We used ferromagnetic particles as a novel technique to deproteinize plasma samples prior to quantitative UHPLC-MS/MS analysis of seven eicosanoids [thromboxane B2 (TXB2), prostaglandin E2 (PGE2), PGD2, 5-hydroxyeicosatetraenoic acid (5-HETE), 11-HETE, 12-HETE, arachidonic acid (AA)]. A combination of ferromagnetic particle enhanced deproteination and subsequent on-line solid phase extraction (on-line SPE) realized quick and convenient semi-automated sample preparation-in contrast to widely used manual SPE techniques which are rather laborious and therefore impede the investigation of AA metabolism in larger patient cohorts. Method evaluation was performed according to a protocol based on the EMA guideline for bioanalytical method validation, modified for endogenous compounds. Calibrators were prepared in ethanol. The calibration curves were found to be linear in a range of 0.1-80ngmL(-1) (TXB2, PGE2, PGD2), 0.05-40ngmL(-1) (5-HETE, 11-HETE), 0.5-400ngmL(-1) (12-HETE) and 25-9800ngmL(-1) (AA). Regarding all analytes and all quality controls, the resulting precision data (inter-assay 2.6 %-15.5 %; intra-assay 2.5 %-15.1 %, expressed as variation coefficient) as well as the accuracy results (inter-assay 93.3 %-125 %; intra-assay 91.7 %-114 %) were adequate. Further experiments addressing matrix effect, recovery and robustness, yielded also very satisfying results. As a proof of principle, the newly developed LC-MS/MS assay was employed to determine the capacity of AA metabolite release after whole blood stimulation in healthy blood donors. For this purpose, whole blood specimens of 5 healthy blood donors were analyzed at baseline and after a lipopolysaccharide (LPS) induced blood cell activation. In several baseline samples some eicosanoids levels were below the Lower Limit of Quantification. However, in the stimulated samples all chosen eicosanoids (except PGD2) could be quantified. These results, in context with those obtained in validation, demonstrate the applicability of ferromagnetic particles for the sample preparation for eicosanoids in human plasma. Thus, we conclude that ferromagnetic particle enhanced deproteination is a promising novel tool for sample preparation in LC-MS/MS, which is of particular interest for automation in clinical mass spectrometry, e.g. in order to further address eicosanoid analysis in larger patient cohorts.

[1]  P. Isakson,et al.  Rapid quantitation of a large scope of eicosanoids in two models of inflammation: development of an electrospray and tandem mass spectrometry method and application to biological studies. , 1996, Analytical Biochemistry.

[2]  B. Matuszewski,et al.  Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. , 2003, Analytical chemistry.

[3]  D. Tsikas,et al.  Analysis of eicosanoids by LC-MS/MS and GC-MS/MS: a historical retrospect and a discussion. , 2014, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[4]  E. Tremoli,et al.  Eicosanoids and Their Drugs in Cardiovascular Diseases: Focus on Atherosclerosis and Stroke , 2013, Medicinal research reviews.

[5]  L. Holdt,et al.  Sepsis-associated changes of the arachidonic acid metabolism and their diagnostic potential in septic patients* , 2012, Critical care medicine.

[6]  Nico C. van de Merbel,et al.  Quantitative determination of endogenous compounds in biological samples using chromatographic techniques , 2008 .

[7]  T. Grosser,et al.  PROSTANOIDS IN HEALTH AND DISEASE , 1979 .

[8]  Ina Willenberg,et al.  Determining cyclooxygenase-2 activity in three different test systems utilizing online-solid phase extraction-liquid chromatography-mass spectrometry for parallel quantification of prostaglandin E(2), D(2) and thromboxane B(2). , 2015, Journal of chromatography. A.

[9]  D. Tsikas A proposal for comparing methods of quantitative analysis of endogenous compounds in biological systems by using the relative lower limit of quantification (rLLOQ). , 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[10]  U. Ceglarek,et al.  Liquid chromatography-tandem mass spectrometry for the analysis of eicosanoids and related lipids in human biological matrices: a review. , 2014, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[11]  F. Schildberg,et al.  Downregulation of proinflammatory cytokine release in whole blood from septic patients. , 1995, Blood.

[12]  W. Powell Precolumn extraction and reversed-phase high-pressure liquid chromatography of prostaglandins and leukotrienes. , 1987, Analytical biochemistry.

[13]  Guowang Xu,et al.  Serum metabolomics study and eicosanoid analysis of childhood atopic dermatitis based on liquid chromatography-mass spectrometry. , 2014, Journal of proteome research.

[14]  Josef Ecker,et al.  Profiling eicosanoids and phospholipids using LC-MS/MS: principles and recent applications. , 2012, Journal of separation science.

[15]  Jun Yang,et al.  Quantitative profiling method for oxylipin metabolome by liquid chromatography electrospray ionization tandem mass spectrometry. , 2009, Analytical chemistry.

[16]  Kwang-Hyeon Liu,et al.  LC-MS/MS for the simultaneous analysis of arachidonic acid and 32 related metabolites in human plasma: Basal plasma concentrations and aspirin-induced changes of eicosanoids. , 2012, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[17]  J. Trojanowski,et al.  Simultaneous HPLC-MS-MS quantification of 8-iso-PGF(2alpha) and 8,12-iso-iPF(2alpha) in CSF and brain tissue samples with on-line cleanup. , 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[18]  G. Fülgraff Prostaglandins and inflammation. , 1974, Advances in clinical pharmacology.

[19]  E. Dennis,et al.  Targeted lipidomic strategies for oxygenated metabolites of polyunsaturated fatty acids. , 2015, Biochimica et biophysica acta.

[20]  T. Olah,et al.  The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds. , 1999, Rapid communications in mass spectrometry : RCM.

[21]  Roy Macarthur,et al.  Generic approach to validation of small-molecule LC-MS/MS biomarker assays. , 2009, Bioanalysis.

[22]  E. Dennis,et al.  Comprehensive ultra-performance liquid chromatographic separation and mass spectrometric analysis of eicosanoid metabolites in human samples. , 2014, Journal of chromatography. A.

[23]  Michael Vogeser,et al.  Deproteination of serum samples for LC-MS/MS analyses by applying magnetic micro-particles. , 2013, Clinical biochemistry.

[24]  U. Ceglarek,et al.  Fast liquid chromatography-quadrupole linear ion trap-mass spectrometry analysis of polyunsaturated fatty acids and eicosanoids in human plasma. , 2013, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[25]  Xu Zhang,et al.  Systematic metabolomic analysis of eicosanoids after omega-3 polyunsaturated fatty acid supplementation by a highly specific liquid chromatography-tandem mass spectrometry-based method. , 2015, Journal of proteome research.

[26]  R. Murphy,et al.  Electrospray ionization and tandem mass spectrometry of eicosanoids. , 2005, Analytical biochemistry.

[27]  Takao Shimizu,et al.  A multiplex quantitation method for eicosanoids and platelet-activating factor using column-switching reversed-phase liquid chromatography-tandem mass spectrometry. , 2005, Analytical biochemistry.

[28]  D. Balgoma,et al.  Quantitative metabolic profiling of lipid mediators. , 2013, Molecular nutrition & food research.