Development of noise resistant hybrid capacitive-resistive electrodes for wearable robotics, computing and welfare

Myoelectrical signals have many applications in medical, sports, wearable robotics and computing fields. Wet electrodes are widely used to acquire these signals. In contrast, dry contact electrodes and noncontact capacitive coupling electrodes have been developed. However, their use has several limitations. In this research, we developed a hybrid electrode that is capable of both capacitive and resistive recordings by optimizing the sensor input impedance value using a new electrode noise model that contained noise sources. We extend this design so that noise originated during real usage, such as motion artifacts and noise from electric motors is also measured and removed from the sensor output. In experiments, noise analysis and experiments were performed by measuring myoelectrical signals from both upper and lower limbs in realistic situations, including weight lifting, robot arm control, and walking on a treadmill. As the results, we verified that our electrodes were capable of bioelectrical measurements at noise levels comparable to wet electrodes in realistic situations and with high correlation coefficients between both types of sensors.

[1]  G.M. Lyons,et al.  A computer game-based EMG biofeedback system for muscle rehabilitation , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[2]  R E Gander,et al.  Power spectral density of the surface myoelectric signal of the biceps brachii as a function of static load. , 1985, Electromyography and clinical neurophysiology.

[3]  E Donchin,et al.  Brain-computer interface technology: a review of the first international meeting. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[4]  Tzyy-Ping Jung,et al.  A brain-machine interface using dry-contact, low-noise EEG sensors , 2008, 2008 IEEE International Symposium on Circuits and Systems.

[5]  Yoshiyuki Sankai,et al.  Power assist method based on Phase Sequence and muscle force condition for HAL , 2005, Adv. Robotics.

[6]  Yasuhisa Hasegawa,et al.  Intention-based walking support for paraplegia patients with Robot Suit HAL , 2007 .

[7]  P. C. Richardson,et al.  Capacitive electrocardiographic and bioelectric electrodes. , 1969, IEEE transactions on bio-medical engineering.

[8]  P. Bonato,et al.  An EMG-position controlled system for an active ankle-foot prosthesis: an initial experimental study , 2005, 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005..

[9]  Yasuhisa Hasegawa,et al.  Intention-based walking support for paraplegia patients with Robot Suit HAL , 2007, Adv. Robotics.

[10]  Yoshiyuki Sankai,et al.  Development of Hybrid Resistive-Capacitive Electrodes for Electroencephalograms and Electrooculograms , 2013 .

[11]  George N. Saridis,et al.  EMG Pattern Analysis and Classification for a Prosthetic Arm , 1982, IEEE Transactions on Biomedical Engineering.

[12]  André van Schaik,et al.  A new EEG recording system for passive dry electrodes , 2010, Clinical Neurophysiology.

[13]  Kongqiao Wang,et al.  Hand gesture recognition and virtual game control based on 3D accelerometer and EMG sensors , 2009, IUI.

[14]  G. Cauwenberghs,et al.  Micropower non-contact EEG electrode with active common-mode noise suppression and input capacitance cancellation , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[15]  Yoshiyuki Sankai,et al.  Control method of robot suit HAL working as operator's muscle using biological and dynamical information , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[16]  Tzyy-Ping Jung,et al.  Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review , 2010, IEEE Reviews in Biomedical Engineering.

[17]  Gander Re,et al.  Power spectral density of the surface myoelectric signal of the biceps brachii as a function of static load. , 1985 .

[18]  T. D. Clark,et al.  Electric potential probes - new directions in the remote sensing of the human body , 2002 .