The effect of abdominal wall morphology on ultrasonic pulse distortion. Part I. Measurements.

The relative importance of the fat and muscle layers of the human abdominal wall in producing ultrasonic wavefront distortion was assessed by means of direct measurements. Specimens employed included six whole abdominal wall specimens and twelve partial specimens obtained by dividing each whole specimen into a fat and a muscle layer. In the measurement technique employed, a hemispheric transducer transmitted a 3.75-MHz ultrasonic pulse through a tissue section. The received wavefront was measured by a linear array translated in the elevation direction to synthesize a two-dimensional aperture. Insertion loss was also measured at various locations on each specimen. Differences in arrival time and energy level between the measured waveforms and computed references that account for geometric delay and spreading were calculated. After correction for the effects of geometry, the received waveforms were synthetically focused. The characteristics of the distortion produced by each specimen and the quality of the resulting focus were analyzed and compared. The measurements show that muscle produces greater arrival time distortion than fat while fat produces greater energy level distortion than muscle, but that the distortion produced by the entire abdominal wall is not equivalent to a simple combination of distortion effects produced by the layers. The results also indicate that both fat and muscle layers contribute significantly to the distortion of ultrasonic beams by the abdominal wall. However, the spatial characteristics of the distortion produced by fat and muscle layers differ substantially. Distortion produced by muscle layers, as well as focal images aberrated by muscle layers, show considerable anisotropy associated with muscle fiber orientation. Distortion produced by fat layers shows smaller-scale, granular structure associated with scattering from the septa surrounding individual fat lobules. Thick layers of fat may be expected to cause poor image quality due to both scattering and bulk absorption effects, while thick muscle layers may be expected to cause focus aberration due to large arrival time fluctuations. Correction of aberrated focuses using time-shift compensation shows more complete correction for muscle sections than for fat sections, so that correction methods based on phase screen models may be more appropriate for muscle layers than for fat layers.

[1]  C. Dorme,et al.  Ultrasonic beam steering through inhomogeneous layers with a time reversal mirror , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  A. Berkhoff,et al.  Correction of concentrated and distributed aberrations in medical ultrasound imaging , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[3]  R C Waag,et al.  Time-shift compensation of ultrasonic pulse focus degradation using least-mean-square error estimates of arrival time. , 1992, The Journal of the Acoustical Society of America.

[4]  S. Teefey,et al.  Factors affecting image quality and diagnostic efficacy in abdominal sonography: A prospective study of 140 patients , 1993, Journal of clinical ultrasound : JCU.

[5]  T. D. Mast,et al.  Simulation of ultrasonic pulse propagation through the abdominal wall. , 1997, The Journal of the Acoustical Society of America.

[6]  G Kossoff,et al.  Correction of distortion in US images caused by subcutaneous tissues: results in tissue phantoms and human subjects. , 1995, Radiology.

[7]  R C Waag,et al.  Measurements of ultrasonic pulse arrival time and energy level variations produced by propagation through abdominal wall. , 1994, The Journal of the Acoustical Society of America.

[8]  M. O'Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: measurements , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  G E Trahey,et al.  Phased array ultrasound imaging through planar tissue layers. , 1986, Ultrasound in medicine & biology.

[10]  M. Kunin Bridging septa of the perinephric space: anatomic, pathologic, and diagnostic considerations. , 1986, Radiology.

[11]  D Rachlin Direct estimation of aberrating delays in pulse-echo imaging systems. , 1990, The Journal of the Acoustical Society of America.

[12]  S. W. Smith,et al.  Phase aberration correction in medical ultrasound using speckle brightness as a quality factor. , 1989, The Journal of the Acoustical Society of America.

[13]  W. Walker,et al.  A speckle target adaptive imaging technique in the presence of distributed aberrations , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  G Kossoff,et al.  A sonographic technique to reduce beam distortion by curved interfaces. , 1989, Ultrasound in medicine & biology.

[15]  Erratum: “Simulation of ultrasonic pulse propagation through the abdominal wall” [J. Acoust. Soc. Am. 102, 1177–1190 (1997)] , 1998 .

[16]  D. Hassler,et al.  Measurement of Spatial Time-Of-Flight Fluctuations of Ultrasound Pulses Passing Through Inhomogeneous Layers , 1987, IEEE 1987 Ultrasonics Symposium.

[17]  A Lorenz,et al.  Ultrasound image properties influenced by abdominal wall thickness and composition , 1993, Journal of clinical ultrasound : JCU.

[18]  J. M. Thijssen,et al.  Influence of absorbing and scattering media on the propagation of ultrasound , 1989 .

[19]  F. Dunn,et al.  Compilation of empirical ultrasonic properties of mammalian tissues. II. , 1980, The Journal of the Acoustical Society of America.

[20]  F. Dunn,et al.  Comprehensive compilation of empirical ultrasonic properties of mammalian tissues. , 1978, The Journal of the Acoustical Society of America.

[21]  Hong Wang,et al.  Phase aberration correction and motion compensation for ultrasonic hyperthermia phased arrays: experimental results , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  R C Chivers,et al.  Ultrasonic velocity and attenuation in mammalian tissues. , 1978, The Journal of the Acoustical Society of America.

[23]  R C Waag,et al.  Correction of ultrasonic wavefront distortion using backpropagation and a reference waveform method for time-shift compensation. , 1994, The Journal of the Acoustical Society of America.

[24]  R C Waag,et al.  Measurement and correction of ultrasonic pulse distortion produced by the human breast. , 1995, The Journal of the Acoustical Society of America.

[25]  T. M. Burke,et al.  Waveform aberrations in an animal model , 1994, 1994 Proceedings of IEEE Ultrasonics Symposium.

[26]  M. Langer,et al.  Fat as a factor affecting resolution in diagnostic ultrasound: possibilities for improving picture quality. , 1985, European journal of radiology.

[27]  Robert C. Waag,et al.  Measurements of ultrasonic pulse arrival time differences produced by abdominal wall specimens. , 1990, The Journal of the Acoustical Society of America.