Hot‐Film Anemometer Velocity Measurements of Arterial Blood Flow in Horses

Blood velocity measurements were carried out using a constant-temperature hot-film anemometer system in both anesthetized and conscious horses. Catheter probes were used to measure velocity wave forms in conscious horses and L-shaped needle probes inserted by direct vessel puncture were used to measure the profiles in regions of the thoracic and abdominal aorta of anesthetized, open-chest horses. Both catheter and L-shaped probes were used for coronary velocity wave-form measurements. The flow conditions were characterized by peak Reynolds numbers of 200–10,000 and unsteadiness parameter of 2–30. These measurements indicate that in the thoracic aorta the flow at peak systole is largely inviscid with a thin-wall boundary layer; in the abdominal aorta the flow is more fully developed but skewed due to branching effects. Highly disturbed flows were observed in the thoracic aorta of both anesthetized and conscious horses, but not in the abdominal aortic region or in the coronary arteries. The results of this study indicate that the flow in the arterial system, although in many cases laminar and disturbance free, is extremely varied in character. It may be asymmetric and certainly is not representative of fully developed, Poiseuille flow.

[1]  L. P.,et al.  Modern Developments in Fluid Dynamics , 1939, Nature.

[2]  H. P. Pieper Catheter-tip manometer for measuring blood pressure during g changes. , 1967, Journal of applied physiology.

[3]  D J Patel,et al.  Application of Heated‐Film Velocity and Shear Probes to Hemodynamic Studies , 1968, Circulation research.

[4]  D. L. Fry Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients , 1968, Circulation research.

[5]  R C Schroter,et al.  Flow patterns in models of the human bronchial airways. , 1969, Respiration physiology.

[6]  N. Wood,et al.  An apparatus for calibrating velocity probes in liquids , 1969 .

[7]  R. Nerem Fluid mechanical aspects of blood flow , 1969 .

[8]  G. Lee,et al.  Velocity Profiles in the Main Pulmonary Artery of Dogs and Man, Measured with a Thin‐Film Resistance Anemometer , 1970, Circulation research.

[9]  N. Wood,et al.  Development and evaluation of a hot-film velocity probe for cardiovascular studies. , 1970, Cardiovascular research.

[10]  Tunstall Pedoe Velocity distribution of blood flow in major arteries of animals and man , 1970 .

[11]  R. Schroter,et al.  Atheroma and arterial wall shear - Observation, correlation and proposal of a shear dependent mass transfer mechanism for atherogenesis , 1971, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[12]  N. Wood,et al.  Velocity patterns in the aorta. , 1971, Cardiovascular research.

[13]  H. Falsetti,et al.  Sequential Velocity Development in the Ascending and Descending Aorta of the Dog , 1972, Circulation research.