Accurate fault location algorithm for transmission lines in the presence of shunt-connected flexible AC transmission system devices

In this study a non-iterative fault location algorithm for shunt-compensated transmission lines is proposed. Since this method does not utilise the model of the shunt compensator, the errors resulted from modelling of the shunt compensators are eliminated. In addition, the new algorithm is not an iterative one and does not require proposing a selector to determine the fault section with respect to the compensator location. In this method, synchronous data from both ends of transmission line are used and distributed parameter line model in time domain is considered. This algorithm consists of three steps. In the first and second steps, it is assumed that the fault is located on the left- and right-hand side of the compensator, respectively. Two discretised equations with respect to these steps are obtained which are used to derive an optimisation problem in the third step. The location of fault and its resistance are determined by solving this problem. This method is applicable for all transmission lines compensated by any shunt device. A 300 km/345 kV transmission line compensated by STATic synchronous COMpensator (STATCOM) simulated in PSCAD/EMTDC has been used to evaluate the performance of the algorithm. The simulation results verify the high accuracy of the method.

[1]  R. Feuillet,et al.  Accurate fault location algorithm for power transmission lines , 2007 .

[2]  Richard Stobart ACCURATE TO A FAULT , 1991 .

[3]  Damir Novosel,et al.  Unsynchronized two-terminal fault location estimation , 1996 .

[4]  Ying-Hong Lin,et al.  An adaptive PMU based fault detection/location technique for transmission lines. I. Theory and algorithms , 2000 .

[5]  Haifaa Abdulla Almteiri Ground fault location on a transmission line using high frequency transient voltages , 2011 .

[6]  Yuan Liao Unsynchronized Fault Location Based on Distributed Parameter Line Model , 2007 .

[7]  Enrique Acha,et al.  FACTS: Modelling and Simulation in Power Networks , 2004 .

[8]  Chul-Hwan Kim,et al.  New settings-free fault location algorithm based on synchronised sampling , 2011 .

[9]  S. L. Hurst Digital protection for power systems , 1997 .

[10]  Jun Qi,et al.  An accurate fault location algorithm for transmission line based on R–L model parameter identification , 2005 .

[11]  P. Gale,et al.  Fault location on transmission lines , 1997 .

[12]  T. J. Hammons,et al.  Flexible AC transmission systems (FACTS) , 1997 .

[13]  R. Feuillet,et al.  Accurate fault location algorithm for series compensated transmission lines , 2000 .

[14]  Li Ran,et al.  An online fault-locating scheme for EHV/UHV transmission lines , 2008 .

[15]  Mladen Kezunovic,et al.  An accurate fault location algorithm using synchronized sampling , 1994 .

[16]  Chul-Hwan Kim,et al.  New Approach for Fault Location on Transmission Lines Not Requiring Line Parameters , 2009 .