A double-sided fabrication process for intrafascicular parylene C based electrode arrays

After the development of a single-sided fabrication process for intrafascicular parylene C based electrode arrays tests showed that an increase in integration density can only be achieved by a double-side process. The process uses 25 μm thick platinum iridium foil, which is thinned down with the laser and sandwiched between two 10 μm thick parylene C layers. Utilizing a picosecond laser (355 nm Nd:YVO4) it was possible to fabricate 40 μm thick electrodes that can be implanted directly in the nerve without relying on additional support layers like chitosan or silk. The fabricated samples feature three 80 μm diameter electrodes on each side and a large ground electrode that is opened to both sides. Impedance mismatches from front to back side as a result of the fabrication process are compensated by electrochemical deposition of nanostructured platinum. This step makes it possible to bring the impedances of the small electrodes down to the range of just a few kΩ at 1 kHz and illustrate the additionally gained surface due to the picosecond laser ablation on the front side electrodes. The safely injectable charge per pulse was found to be 635.75 μC/cm2 for such coated electrodes. Optical investigations show that this fabrication process offers an alternative to established lithographic processes for thin and flexible electrode arrays in neural implants.

[1]  W. F. Gorham A New, General Synthetic Method for the Preparation of Linear Poly‐p‐xylylenes , 1966 .

[2]  T. Stieglitz,et al.  Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces , 2000 .

[3]  T. Stieglitz,et al.  Development of a single-sided Parylene C based intrafascicular multichannel electrode for peripheral nerves , 2015, 2015 7th International IEEE/EMBS Conference on Neural Engineering (NER).

[4]  David L. Kaplan,et al.  Silk-Backed Structural Optimization of High-Density Flexible Intracortical Neural Probes , 2015, Journal of Microelectromechanical Systems.

[5]  T Stieglitz,et al.  Nanostructured platinum grass enables superior impedance reduction for neural microelectrodes. , 2015, Biomaterials.

[6]  G J Suaning,et al.  Fabrication of implantable microelectrode arrays by laser cutting of silicone rubber and platinum foil , 2005, Journal of neural engineering.

[7]  M. Kaltenbrunner,et al.  An ultra-lightweight design for imperceptible plastic electronics , 2013, Nature.

[8]  Thomas Stieglitz,et al.  Thin films and microelectrode arrays for neuroprosthetics , 2012 .

[9]  T. Stieglitz,et al.  High density interconnects and flexible hybrid assemblies for active biomedical implants , 2001 .

[10]  T. Stieglitz,et al.  A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve. , 2010, Biosensors & bioelectronics.

[11]  N H Lovell,et al.  Laser patterning of platinum electrodes for safe neurostimulation , 2014, Journal of neural engineering.