Propagation of the hip joint centre location error to the estimate of femur vs pelvis orientation using a constrained or an unconstrained approach.

To estimate hip joint angles during selected motor tasks using stereophotogrammetric data, it is necessary to determine the hip joint centre position. The question is whether the errors affecting that determination propagate less to the angles estimates when a three degrees of freedom (DOFs) constraint (spherical hinge) is used between femur and pelvis, rather than when the two bones are assumed to be unconstrained (six DOFs). An analytical relationship between the hip joint centre location error and the joint angle error was obtained limited to the planar case. In the 3-D case, a similar relationship was obtained using a simulation approach based on experimental data. The joint angle patterns resulted in a larger distortion using a constrained approach, especially when wider rotations occur. The range of motion of the hip flexion-extension, obtained simulating different location errors and without taking into account soft tissue artefacts, varied approximately 7 deg using a constrained approach and up to 1 deg when calculated with an unconstrained approach. Thus, the unconstrained approach should be preferred even though its estimated three linear DOFs most unlikely carry meaningful information.

[1]  A Cappello,et al.  Effects of hip joint centre mislocation on gait analysis results. , 2000, Journal of biomechanics.

[2]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[3]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[4]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[5]  M P Kadaba,et al.  Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[6]  A Leardini,et al.  Position and orientation in space of bones during movement: anatomical frame definition and determination. , 1995, Clinical biomechanics.

[7]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation. , 2005, Gait & posture.

[8]  Aurelio Cappozzo,et al.  An optimized protocol for hip joint centre determination using the functional method. , 2006, Journal of biomechanics.

[9]  S Toksvig-Larsen,et al.  Validation of a functional method for the estimation of hip joint centre location. , 1999, Journal of biomechanics.

[10]  D A Dennis,et al.  "In vivo" determination of hip joint separation and the forces generated due to impact loading conditions. , 2001, Journal of biomechanics.

[11]  R. B. Davis,et al.  A gait analysis data collection and reduction technique , 1991 .

[12]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 1: theoretical background. , 2005, Gait & posture.