Transvenous Stent-assisted Coil Embolization for Management of Dehiscent High Jugular Bulb With Tinnitus and Contralateral Hypoplastic Venous Sinuses.

OBJECTIVES This study aimed to evaluate the safety and efficacy of transvenous stent-assisted coil embolization for dehiscent high jugular bulb (HJB) with tinnitus and contralateral hypoplastic venous sinus. STUDY DESIGN Case series with chart review. SETTING Tertiary academic medical center. METHODS From September 2008 to October 2018, a series of patients with dehiscent HJB presenting with intractable pulsatile tinnitus abated only by ipsilateral jugular vein compression were included. Patients underwent transvenous stent-assisted coil embolization for selective obstruction to the dome of the HJB due to hypoplastic contralateral transverse or sigmoid venous sinus. Technical safety and clinical efficacy were retrospectively analyzed. Clinical outcome measurements included pure-tone audiogram, tinnitus character, and tinnitus handicap inventory and evaluated based on the change during the first 6 months after the procedure. RESULTS Subjects included five patients with dehiscent HJB and troublesome pulsatile tinnitus who refused surgery (n = 4), or who experienced recurrence after surgical covering and reinforcement using autologous cartilage (n = 1). The mean age of the five patients (only female) was 45 years. Transvenous stent-assisted coil embolization was technically successful in all patients with symptomatic dehiscent HJB, with no procedure-related complications. Temporary postprocedural headache was observed in two patients, but resolved within 3 days. Symptoms were completely resolved in all cases. There was no recurrence or aggravation of tinnitus during follow-up period. CONCLUSIONS Transvenous stent-assisted coil embolization for dehiscent HJB with tinnitus and contralateral hypoplastic transverse or sigmoid venous sinus could be a technically safe and clinically effective treatment strategy while preserving cranial venous drainage.

[1]  D. Coelho,et al.  Hydroxyapatite cement resurfacing the dehiscent jugular bulb: Novel treatment for pulsatile tinnitus , 2018, The Laryngoscope.

[2]  E. Karabulut,et al.  Radiological and audiometric evaluation of high jugular bulb and dehiscent high jugular bulb. , 2016, The Journal of laryngology and otology.

[3]  T. Neumann-Haefelin,et al.  Pulsatile tinnitus: imaging and differential diagnosis. , 2013, Deutsches Arzteblatt international.

[4]  S. Merchant,et al.  A clinical and histopathologic study of jugular bulb abnormalities. , 2012, Archives of otolaryngology--head & neck surgery.

[5]  A. Rabie,et al.  A novel surgical technique for management of tinnitus due to high dehiscent jugular bulb , 2010, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[6]  A. Lalwani,et al.  Clinical spectrum of patients with erosion of the inner ear by jugular bulb abnormalities , 2009, The Laryngoscope.

[7]  T. Lee,et al.  Management of High Jugular Bulb with Tinnitus: Transvenous Stent-Assisted Coil Embolization , 2008, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[8]  C. Danner Middle ear atelectasis: what causes it and how is it corrected? , 2006, Otolaryngologic clinics of North America.

[9]  Y. Young,et al.  Dehiscent High Jugular Bulb: A Pitfall in Middle Ear Surgery , 2006, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[10]  M. Sluzewski,et al.  Packing density in coiling of small intracranial aneurysms. , 2006, AJNR. American journal of neuroradiology.

[11]  T. Kubo,et al.  Management of Hemorrhagic High Jugular Bulb with Adhesive Otitis Media in an Only Hearing Ear: Transcatheter Endovascular Embolization Using Detachable Coils , 2004, The Annals of otology, rhinology, and laryngology.

[12]  A. Bozorg Grayeli,et al.  Surgical treatment of the high jugular bulb in patients with Ménière’s disease and pulsatile tinnitus , 1999, European Archives of Oto-Rhino-Laryngology.

[13]  M. Shikowitz,et al.  High Jugular Bulb and Conductive Hearing Loss , 1997, The Laryngoscope.

[14]  W. Doyle,et al.  Gas exchange across the middle ear mucosa in monkeys. Estimation of exchange rate. , 1995, Archives of otolaryngology--head & neck surgery.

[15]  J. Nadol,et al.  High Jugular Bulb: Implications for Posterior Fossa Neurotologic and Cranial Base Surgery , 1993, The Annals of otology, rhinology, and laryngology.

[16]  H. Wilbrand,et al.  THE Jugular Bulb Diverticulum , 1986, Acta radiologica: diagnosis.

[17]  H. Wilbrand,et al.  The Topographic Relations of the High Jugular Fossa to the Inner Ear , 1986, Acta radiologica: diagnosis.

[18]  C. Sasaki,et al.  Pulsatile tinnitus arising from jugular megabulb deformity: A treatment rationale , 1983, The Laryngoscope.

[19]  F. Schelling [The emissaries of the human skull (author's transl)]. , 1978, Anatomischer Anzeiger.

[20]  F. N. Ritter,et al.  A high placed jugular bulb in the middle ear: A clinical and temporal bone study , 1973, The Laryngoscope.