Elastomer-glass micropump employing active throttles.

We report a reciprocating microfluidic pump, the Micro Throttle Pump (MTP), constructed in a relatively uncomplicated manner from glass and microstructured poly(dimethylsiloxane)(PDMS). Unconventionally, the MTP employs throttling of fluid flow as distinct from fully-closing valve structures. Accordingly, this technique offers the prospect of solid-phase suspension tolerance. The reported MTP employs piezoelectrically (PZT) actuated deformation of flow constrictions (throttles) fabricated from PDMS at the two ports of a central, PZT actuated pump chamber. By appropriate time-sequencing of the individual PZTs' actuation, pumping can be induced in either direction. PDMS' elasticity further facilitates throttle operation by virtue of allowing significant PZT flexure that is substantially independent of the underlying PDMS microstructure. In contrast, in a rigid substrate such as silicon, deformation is constrained to where underlying microstructured cavities exist and this restricts design options. We describe the construction and performance of a prototype MTP capable of pumping 300 microl min(-1) or alternatively generating a back-pressure of 5.5 kPa. Preliminary modelling of MTP operation is also presented.

[1]  William H. Grover,et al.  Monolithic membrane valves and diaphragm pumps for practical large-scale integration into glass microfluidic devices , 2003 .

[2]  Yu-Hwa Lo,et al.  UV/ozone modification of poly(dimethylsiloxane) microfluidic channels , 2004 .

[3]  Jian Zhang,et al.  Polymerization optimization of SU-8 photoresist and its applications in microfluidic systems and MEMS , 2001 .

[4]  G. Whitesides,et al.  Poly(dimethylsiloxane) as a material for fabricating microfluidic devices. , 2002, Accounts of chemical research.

[5]  Ulf W. Gedde,et al.  Hydrophobicity Recovery of Polydimethylsiloxane after Exposure to Corona Discharges , 1998 .

[6]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[7]  P. Kaye,et al.  A silicon micromachined device for use in blood cell deformability studies , 1995, IEEE Transactions on Biomedical Engineering.

[8]  I. D. Johnston,et al.  A novel instrument for studying the flow behaviour of erythrocytes through microchannels simulating human blood capillaries. , 1997, Microvascular research.

[9]  J. Genzer,et al.  Surface modification of Sylgard-184 poly(dimethyl siloxane) networks by ultraviolet and ultraviolet/ozone treatment. , 2002, Journal of colloid and interface science.

[10]  Peter Enoksson,et al.  A Valve-Less Diffuser Micropump for Microfluidic Analytical Systems , 2001 .

[11]  Paul C. H. Li,et al.  Transport, manipulation, and reaction of biological cells on-chip using electrokinetic effects. , 1997, Analytical chemistry.