Thermal-mechanical-noise-based CMUT characterization and sensing

When capacitive micromachined ultrasonic transducers (CMUTs) are monolithically integrated with custom-designed low-noise electronics, the output noise of the system can be dominated by the CMUT thermal-mechanical noise both in air and in immersion even for devices with low capacitance. Because the thermal-mechanical noise can be related to the electrical admittance of the CMUTs, this provides an effective means of device characterization. This approach yields a novel method to test the functionality and uniformity of CMUT arrays and the integrated electronics when a direct connection to CMUT array element terminals is not available. Because these measurements can be performed in air at the wafer level, the approach is suitable for batch manufacturing and testing. We demonstrate this method on the elements of an 800-μm-diameter CMUT-on-CMOS array designed for intravascular imaging in the 10 to 20 MHz range. Noise measurements in air show the expected resonance behavior and spring softening effects. Noise measurements in immersion for the same array provide useful information on both the acoustic cross talk and radiation properties of the CMUT array elements. The good agreement between a CMUT model based on finite difference and boundary element methods and the noise measurements validates the model and indicates that the output noise is indeed dominated by thermal-mechanical noise. The measurement method can be exploited to implement CMUT-based passive sensors to measure immersion medium properties, or other parameters affecting the electro-mechanics of the CMUT structure.

[1]  A. Nikoozadeh,et al.  An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  Paul Hasler,et al.  Thermal mechanical noise based characterization of CMUTs using monolithically integrated low noise receiver electronics , 2010, 2010 IEEE International Ultrasonics Symposium.

[3]  Karim G. Sabra,et al.  High frequency ultrasonic imaging using thermal mechanical noise recorded on capacitive micromachined transducer arrays , 2011 .

[4]  F. Teston,et al.  A finite difference model For cMUT devices , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  Gus Gurley,et al.  Short cantilevers for atomic force microscopy , 1996 .

[6]  Elmer V Carlson,et al.  Noise in miniature microphones. , 2002, The Journal of the Acoustical Society of America.

[7]  P.-C. Eccardt,et al.  Analysis of crosstalk between fluid coupled cmut membranes , 2005, IEEE Ultrasonics Symposium, 2005..

[8]  Peter Gerstoft,et al.  Extracting time‐domain Green's function estimates from ambient seismic noise , 2005 .

[9]  J. McLean,et al.  Directional scholte wave generation and detection using interdigital capacitive micromachined ultrasonic transducers , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  D. Certon,et al.  A multiscale model for array of capacitive micromachined ultrasonic transducers. , 2010, The Journal of the Acoustical Society of America.

[11]  G. Feuillard,et al.  Relationship between electrical impedance of a transducer and its electroacoustic behavior: Measurement without primary source , 2006 .

[12]  H. Nyquist Thermal Agitation of Electric Charge in Conductors , 1928 .

[13]  T. Gabrielson Mechanical-thermal noise in micromachined acoustic and vibration sensors , 1993 .

[14]  Richard L. Weaver,et al.  On the emergence of the Green's function in the correlations of a diffuse field: pulse-echo using thermal phonons. , 2001, Ultrasonics.

[15]  H. Mooshofer,et al.  A resonant CMUT sensor for fluid applications , 2009, 2009 IEEE Sensors.

[16]  Toby Xu,et al.  CMUT-on-CMOS for forward-looking IVUS: Improved fabrication and real-time imaging , 2010, 2010 IEEE International Ultrasonics Symposium.

[17]  Arindam Basu,et al.  A Charge-Based Low-Power High-SNR Capacitive Sensing Interface Circuit , 2008, IEEE Transactions on Circuits and Systems I: Regular Papers.

[18]  Paul Hasler,et al.  Front-end receiver electronics for high-frequency monolithic CMUT-on-CMOS imaging arrays , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  C.G. Oakley,et al.  Calculation of ultrasonic transducer signal-to-noise ratios using the KLM model , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  R. Weaver,et al.  Ultrasonics without a source: thermal fluctuation correlations at MHz frequencies. , 2001, Physical review letters.