In situ continuous detection of bacteria on the surface of solid medium with a Bulk Acoustic Wave-Impedance Sensor

A reusable Bulk Acoustic Wave(BAW)-Impedance Sensor has been developed for continuous detection of growth and numbers of Proteus vulgaris on the surface of a solid medium under ordinary conditions. The medium used is NB agar, which is not only suitable for culturing gram-negative intestinal bacilli, but also for monitoring bacteria with a Bulk Acoustic Wave-Impedance Sensor. The method is simple and rapid. The concentration ofthe bacteria can be detected using the proposed method in the range of 3.4 × 102−6.7 × 106 cells/ml.

[1]  L. Nie,et al.  Rapid Detection of Escherichia Coliform Using A Series Electrode Piezoelectric Crystal Sensor , 1994 .

[2]  K.-O. Habermehl Rapid Methods and Automation in Microbiology and Immunology , 1985 .

[3]  I. Karube,et al.  Piezoelectric Crystal Biosensor System for Detection of Escherichia Coli , 1989 .

[4]  J. Gordon,et al.  The oscillation frequency of a quartz resonator in contact with liquid , 1985 .

[5]  Michael Grätzel,et al.  Detection of viruses and bacteria with piezoelectric immunosensors , 1993 .

[6]  L. Nie,et al.  Titrations with piezoelectric monitoring : Part 1. Fundamental theory and titration of acids and bases , 1990 .

[7]  Isao Karube,et al.  Piezoelectric immuno sensor for the detection of candida albicans microbes , 1986 .

[8]  D. R. Turner,et al.  New Instrumental Methods in Electrochemistry , 1955 .

[9]  T. Hattori The viable count: quantitative and environmental aspects. , 1988 .

[10]  G G Guilbault,et al.  Piezoelectric crystal biosensors. , 1990, Biosensors & bioelectronics.

[11]  Wilfred H. Nelson,et al.  Instrumental Methods for Rapid Microbiological Analysis , 1985 .

[12]  E Tamiya,et al.  Piezoelectric crystal biosensor modified with protein A for determination of immunoglobulins. , 1987, Analytical chemistry.

[13]  P. Woias,et al.  Biosensors based on piezoelectric crystals , 1990 .

[14]  Shouzhuo Yao,et al.  A goat-anti-human IgG modified piezoimmunosensor for Staphylococcus aureus detection , 1995 .

[15]  W. H. King Piezoelectric Sorption Detector. , 1964 .

[16]  Wen-Hong Zhu,et al.  Behaviour of a series piezoelectric sensor in electrolyte solution , 1993 .

[17]  David E. Nivens,et al.  Long-term, on-line monitoring of microbial biofilms using a quartz crystal microbalance , 1993 .

[18]  Michael D. Ward,et al.  Piezoelectric Cell Growth Sensor , 1991, Bio/Technology.

[19]  J. Gordon,et al.  Frequency of a quartz microbalance in contact with liquid , 1985 .

[20]  Y. Shou-zhuo,et al.  Frequency properties of a piezoelectric quartz crystal in solutions and application to total salt determination , 1987 .