Restoration and analysis of standing-up in complete paraplegia utilizing functional electrical stimulation.

OBJECTIVE Restoration of stand-up motion in patients with complete paraplegia utilizing multichannel functional electrical stimulation, and analysis of the restored motion. DESIGN Nonrandomized control trial. SETTING General community, a referral center, institutional practice, and ambulatory care: PATIENTS Twelve volunteer samples were used for the collection of normal data. Two complete paraplegics received treatment for the restoration of stand-up motion. MAIN OUTCOME MEASURES The electromyogram, joint angle, and floor reaction force were investigated during standing-up with arms crossed in front of the chest, and hands-assisted standing-up using parallel bars. The maximum knee joint torque during standing-up without hands-assists was calculated using a three-segment link model. Standing-up motion in complete paraplegics was restored, and then analyzed using the three-dimensional floor reaction force and the hip, knee, and ankle angles. RESULTS Main muscles used to stand up were the quadriceps, tibialis anterior, and paraspinal muscles. Hands-assists reduced the muscle activity and the vertical floor reaction force. Peak muscle activity was less during hands-assisted standing-up, except for the rectus femoris and the iliopsoas muscle. The maximum knee joint torque during standing-up was 1.6Nm/kg for both knees. Two complete paraplegics were able to stand up smoothly from a wheelchair based on stimulation data obtained from normal subjects. The characteristic pattern during standing-up was knee flexion preceding extension. CONCLUSION Stand-up motion was restored utilizing electromyogram data and knee joint torque data from normal subjects.

[1]  T Bajd,et al.  Standing-up of a healthy subject and a paraplegic patient. , 1982, Journal of biomechanics.

[2]  N. Hoshimiya,et al.  A multichannel FES system for the restoration of motor functions in high spinal cord injury patients: a respiration-controlled system for multijoint upper extremity , 1989, IEEE Transactions on Biomedical Engineering.

[3]  E. Marsolais,et al.  Functional electrical stimulation for walking in paraplegia. , 1987, The Journal of bone and joint surgery. American volume.

[4]  K Ebata [Measurement of the center of gravity using the link model for controlling functional electrical stimulation]. , 1993, Nihon Seikeigeka Gakkai zasshi.

[5]  Y. Handa A portable multichannel FES system for restoration of motor function of the paralyzed extremities , 1989 .

[6]  R. Burdett,et al.  Biomechanical comparison of rising from two types of chairs. , 1985, Physical therapy.

[7]  Brian J. Andrews,et al.  Ruled-based control of a hybrid FES orthosis for assisting paraplegic locomotion , 1989 .

[8]  G. M. Shambes,et al.  Biomechanical analysis of the sit-to-stand motion in elderly persons. , 1992, Archives of physical medicine and rehabilitation.

[9]  N. Hoshimiya,et al.  Development of percutaneous intramuscular electrode for multichannel FES system , 1989, IEEE Transactions on Biomedical Engineering.

[10]  K H Mauritz,et al.  Control mechanisms for restoring posture and movements in paraplegics. , 1989, Progress in brain research.

[11]  M. Munih,et al.  Analysis of standing up and sitting down in humans: definitions and normative data presentation. , 1990, Journal of biomechanics.

[12]  Robertw . Mann,et al.  Whole-body movements during rising to standing from sitting. , 1990, Physical therapy.