High-spatial-resolution multistation MR imaging of lower-extremity peripheral vasculature with segmented volume acquisition: feasibility study.

A method of three-station three-dimensional magnetic resonance (MR) angiography of the lower extremities with segmented volume acquisition is presented. Three-dimensional MR angiographic data were acquired in two passes, with the central k-space views acquired during the arterial phase for the more proximal stations. This allowed a faster bolus injection rate and potentially improved visualization of the tibioperoneal arteries.

[1]  S J Riederer,et al.  Theoretical limits of spatial resolution in elliptical‐centric contrast‐enhanced 3D‐MRA , 1999, Magnetic resonance in medicine.

[2]  M. Prince,et al.  Pulmonary magnetic resonance angiography , 1999, Journal of magnetic resonance imaging : JMRI.

[3]  T K Foo,et al.  Automated bolus chase peripheral MR angiography: Initial practical experiences and future directions of this work‐in‐progress , 1999, Journal of magnetic resonance imaging : JMRI.

[4]  A. Kassner,et al.  Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: preliminary experience. , 1999, Radiology.

[5]  J. V. van Engelshoven,et al.  MR angiography of run-off vessels , 1999, European Radiology.

[6]  S DeSena,et al.  Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation. , 1998, Radiology.

[7]  Vincent B. Ho,et al.  Optimization of Gadolinium-Enhanced Magnetic Resonance Angiography Using an Automated Bolus-Detection Algorithm (MR SmartPrep)y , 1998 .

[8]  M R Prince,et al.  Optimizing three-dimensional gadolinium-enhanced magnetic resonance angiography. Original investigation. , 1998, Investigative radiology.

[9]  M. R. Prince,et al.  Contrast-enhanced MR angiography , 1998, Abdominal Imaging.

[10]  H M Lee,et al.  Dynamic k‐space filling for bolus chase 3D MR digital subtraction angiography , 1998, Magnetic resonance in medicine.

[11]  J. Debbins,et al.  Arterial phase carotid and vertebral artery imaging in 3D contrast‐enhanced MR angiography by combining fluoroscopic triggering with an elliptical centric acquisition order , 1998, Magnetic resonance in medicine.

[12]  Y. Wang,et al.  Timing algorithm for bolus chase MR digital subtraction angiography , 1998, Magnetic resonance in medicine.

[13]  J. V. van Engelshoven,et al.  Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography. , 1998, Radiology.

[14]  S J Riederer,et al.  Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath‐hold three‐dimensional gradient echo imaging , 1997, Magnetic resonance in medicine.

[15]  T. Chenevert,et al.  Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography. , 1997, Radiology.

[16]  T K Foo,et al.  Contrast-enhanced abdominal MR angiography: optimization of imaging delay time by automating the detection of contrast material arrival in the aorta. , 1997, Radiology.

[17]  T K Foo,et al.  Fast three‐dimensional time‐of‐flight MR angiography of the intracranial vasculature , 1995, Journal of magnetic resonance imaging : JMRI.

[18]  M. Prince Gadolinium-enhanced MR aortography. , 1990, Radiology.

[19]  W. Shiels,et al.  Air enema for diagnosis and reduction of intussusception: clinical experience and pressure correlates. , 1991, Radiology.