Assessment of microdamage caused by orthodontic miniscrew pilot holes
暂无分享,去创建一个
[1] J. Codrington,et al. The influence of miniscrew insertion torque , 2018, European journal of orthodontics.
[2] J. Codrington,et al. Influence of cortical bone thickness on miniscrew microcrack formation , 2017, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[3] E. M. Boeck,et al. EFFECT OF ANGLED INSTALLATION OF ORTHODONTIC MINI-IMPLANTS ON PRIMARY STABILITY , 2014 .
[4] M. Allen,et al. Orthodontic mini-implant diameter does not affect in-situ linear microcrack generation in the mandible or the maxilla. , 2012, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[5] William P. Neace,et al. Microdamage of the cortical bone during mini-implant insertion with self-drilling and self-tapping techniques: a randomized controlled trial. , 2012, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[6] S. Huja,et al. Bone damage associated with orthodontic placement of miniscrew implants in an animal model. , 2012, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[7] Seçil Çehreli,et al. Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants. , 2012, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[8] William Robert Walsh,et al. Drilling of Bone: Practicality, Limitations and Complications Associated with Surgical Drill-Bits , 2011 .
[9] D. Drescher,et al. Impact of bone quality, implant type, and implantation site preparation on insertion torques of mini-implants used for orthodontic anchorage. , 2011, International journal of oral and maxillofacial surgery.
[10] J. Nyman,et al. Differences in the mechanical behavior of cortical bone between compression and tension when subjected to progressive loading. , 2009, Journal of the mechanical behavior of biomedical materials.
[11] M. Hans,et al. Buccal cortical bone thickness for mini-implant placement. , 2009, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[12] Benedict Wilmes,et al. Insertion angle impact on primary stability of orthodontic mini-implants. , 2008, The Angle orthodontist.
[13] P. Buschang,et al. 2008 survey of AAO members on miniscrew usage. , 2008, Journal of clinical orthodontics : JCO.
[14] H. Fischer-Brandies,et al. Microdamage in Cortical Bone due to the Overtightening of Orthodontic Microscrews , 2008, Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie.
[15] J. Granjeiro,et al. Dental and skeletal characterization of the BR-1 minipig. , 2007, Veterinary journal.
[16] Benedict Wilmes,et al. Parameters Affecting Primary Stability of Orthodontic Mini-implants , 2006, Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie.
[17] B. Melsen. Mini-implants: Where are we? , 2005, Journal of clinical orthodontics : JCO.
[18] L. Kaban,et al. Histology of the porcine mandibular distraction wound. , 2005, International journal of oral and maxillofacial surgery.
[19] B. Melsen,et al. Miniscrew Implants: The Aarhus Anchorage System , 2005 .
[20] T. Gunnlaugsson,et al. Detecting microdamage in bone , 2003, Journal of anatomy.
[21] R. Martin,et al. Fatigue Microdamage as an Essential Element of Bone Mechanics and Biology , 2003, Calcified Tissue International.
[22] Kaddour Bouazza-Marouf,et al. The detection of drill bit break-through for the enhancement of safety in mechatronic assisted orthopaedic drilling , 1999 .
[23] D. Laskin,et al. Analysis of seating and fracturing torque of bicortical screws. , 1994, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.
[24] J. Boutrand. Biocompatibility and performance of medical devices , 2012 .
[25] Hee-Moon Kyung,et al. Biomechanical and histological comparison of self-drilling and self-tapping orthodontic microimplants in dogs. , 2008, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.
[26] R Kanomi,et al. Mini-implant for orthodontic anchorage. , 1997, Journal of clinical orthodontics : JCO.