A new method to detect ventricular fibrillation from CPR artifact-corrupted ECG based on the ECG alone
暂无分享,去创建一个
Dan Wang | Ming Yu | Guang Zhang | Feng Chen | Liangzhe Li | Zhenxing Song | Tai-Hu Wu | Zongming Wan | F. Chen | Dan Wang | Tai-Hu Wu | Liangzhe Li | Ming Yu | Guang-fang Zhang | Zongming Wan | Zhenxing Song
[1] T. Rea,et al. Incidence of EMS-treated out-of-hospital cardiac arrest in Europe. , 2005, Resuscitation.
[2] Wanchun Tang,et al. Adverse Outcomes of Interrupted Precordial Compression During Automated Defibrillation , 2002, Circulation.
[3] Trygve Eftestøl,et al. Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithm , 2002, IEEE Transactions on Biomedical Engineering.
[4] Yongqin Li,et al. Techniques for artefact filtering from chest compression corrupted ECG signals: good, but not enough. , 2009, Resuscitation.
[5] Hans G. Feichtinger,et al. CPR Artifact Removal in Ventricular Fibrillation ECG Signals Using Gabor Multipliers , 2009, IEEE Transactions on Biomedical Engineering.
[6] George A. Mensah,et al. Sudden Cardiac Death in the United States, 1989 to 1998 , 2001, Circulation.
[7] Tobias Werther,et al. Reduction of CPR artifacts in the ventricular fibrillation ECG by coherent line removal , 2010, Biomedical engineering online.
[8] Roger D. White,et al. Technologic advances and program initiatives in public access defibrillation using automated external defibrillators , 2001, Current opinion in critical care.
[9] Jesus Ruiz,et al. Detection of ventricular fibrillation in the presence of cardiopulmonary resuscitation artefacts. , 2007, Resuscitation.
[10] Cantab Ma,et al. Emanuel Miller. M.A. Cantab., F.R.C.P., D.P.M. , 1970 .
[11] Jeffrey M. Hausdorff,et al. Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .
[12] M. Eisenberg,et al. SENSITIVITY, ACCURACY, AND SAFETY OF AN AUTOMATIC EXTERNAL DEFIBRILLATOR Report of a Field Evaluation , 1984, The Lancet.
[13] Karl Unterkofler,et al. Detecting Ventricular Fibrillation by Time-Delay Methods , 2007, IEEE Transactions on Biomedical Engineering.
[14] Jesus Ruiz,et al. A method to remove CPR artefacts from human ECG using only the recorded ECG. , 2008, Resuscitation.
[15] D J Roe,et al. Outcomes of rapid defibrillation by security officers after cardiac arrest in casinos. , 2000, The New England journal of medicine.
[16] Maaret Castrén,et al. European Resuscitation Council Guidelines for Resuscitation 2010 Section 2. Adult basic life support and use of automated external defibrillators , 2010, Resuscitation.
[17] David E. Snyder,et al. Wide variation in cardiopulmonary resuscitation interruption intervals among commercially available automated external defibrillators may affect survival despite high defibrillation efficacy , 2004, Critical care medicine.
[18] Trygve Eftestøl,et al. CPR artifact removal from human ECG using optimal multichannel filtering , 2000, IEEE Transactions on Biomedical Engineering.
[19] Wanchun Tang,et al. Adverse effects of interrupting precordial compression during cardiopulmonary resuscitation. , 1997, Critical care medicine.
[20] Trygve Eftestøl,et al. A Least Mean-Square Filter for the Estimation of the Cardiopulmonary Resuscitation Artifact Based on the Frequency of the Compressions , 2009, IEEE Transactions on Biomedical Engineering.
[21] P. Steen,et al. Reducing CPR artefacts in ventricular fibrillation in vitro. , 2001, Resuscitation.
[22] Yongqin Li,et al. An Algorithm Used for Ventricular Fibrillation Detection Without Interrupting Chest Compression , 2012, IEEE Transactions on Biomedical Engineering.
[23] S. O. Aase,et al. Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG. , 2004, Resuscitation.
[24] Greg Sinibaldi,et al. Incidence of EMS-treated out-of-hospital cardiac arrest in the United States. , 2004, Resuscitation.
[25] Tobias Werther,et al. Strong corruption of electrocardiograms caused by cardiopulmonary resuscitation reduces efficiency of two-channel methods for removing motion artefacts in non-shockable rhythms. , 2009, Resuscitation.
[26] Joel Xue,et al. Statistical evaluation of reproducibility of automated ECG measurements: An example from arrhythmogenic right ventricular dysplasia/cardiomyopathy clinic , 2014, Biomed. Signal Process. Control..
[27] Robert A. Berg,et al. Importance of Continuous Chest Compressions During Cardiopulmonary Resuscitation: Improved Outcome During a Simulated Single Lay-Rescuer Scenario , 2002, Circulation.
[28] Klaus Rheinberger,et al. Removal of CPR Artifacts From the Ventricular Fibrillation ECG by Adaptive Regression on Lagged Reference Signals , 2008, IEEE Transactions on Biomedical Engineering.
[29] R W Koster,et al. Out-of-hospital cardiac arrests in Amsterdam and its surrounding areas: results from the Amsterdam resuscitation study (ARREST) in 'Utstein' style. , 1998, Resuscitation.
[30] P. Steen,et al. Effects of Interrupting Precordial Compressions on the Calculated Probability of Defibrillation Success During Out-of-Hospital Cardiac Arrest , 2002 .
[31] R. Koster,et al. Interruption of cardiopulmonary resuscitation with the use of the automated external defibrillator in out-of-hospital cardiac arrest. , 2003, Annals of emergency medicine.