Optimizing Electrode Configuration for Electrical Impedance Measurements of Muscle via the Finite Element Method

Electrical impedance myography (EIM) is a technique for the evaluation of neuromuscular diseases, including amyotrophic lateral sclerosis and muscular dystrophy. In this study, we evaluated how alterations in the size and conductivity of muscle and thickness of subcutaneous fat impact the EIM data, with the aim of identifying an optimized electrode configuration for EIM measurements. Finite element models were developed for the human upper arm based on anatomic data; material properties of the tissues were obtained from rat and published sources. The developed model matched the frequency-dependent character of the data. Of the three major EIM parameters, resistance, reactance, and phase, the reactance was least susceptible to alterations in the subcutaneous fat thickness, regardless of electrode arrangement. For example, a quadrupling of fat thickness resulted in a 375% increase in resistance at 35 kHz but only a 29% reduction in reactance. By further optimizing the electrode configuration, the change in reactance could be reduced to just 0.25%. For a fixed 30 mm distance between the sense electrodes centered between the excitation electrodes, an 80 mm distance between the excitation electrodes was found to provide the best balance, with a less than 1% change in reactance despite a doubling of subcutaneous fat thickness or halving of muscle size. These analyses describe a basic approach for further electrode configuration optimization for EIM.

[1]  Lucy L. Wang,et al.  Assessment of Alterations in the Electrical Impedance of Muscle After Experimental Nerve Injury via Finite-Element Analysis , 2011, IEEE Transactions on Biomedical Engineering.

[2]  Mohammad A Ahad,et al.  Electrical characteristics of rat skeletal muscle in immaturity, adulthood and after sciatic nerve injury, and their relation to muscle fiber size , 2009, Physiological measurement.

[3]  Spatial dependence of the phase in localized bioelectrical impedance analysis. , 2001, Physics in medicine and biology.

[4]  The effect of subacute denervation on the electrical anisotropy of skeletal muscle: Implications for clinical diagnostic testing , 2010, Clinical Neurophysiology.

[5]  Seward B Rutkove,et al.  Localized bioimpedance analysis in the evaluation of neuromuscular disease , 2002, Muscle & nerve.

[6]  Naven Duggal,et al.  Electrical impedance myography in the assessment of disuse atrophy. , 2009, Archives of physical medicine and rehabilitation.

[7]  Lucy Lu Wang,et al.  Electrical impedance myography for monitoring motor neuron loss in the SOD1 G93A amyotrophic lateral sclerosis rat , 2011, Clinical Neurophysiology.

[8]  Seward B Rutkove,et al.  Utilizing a handheld electrode array for localized muscle impedance measurements , 2012, Muscle & nerve.

[9]  K. Foster,et al.  Anisotropy in the dielectric properties of skeletal muscle , 2006, Medical and Biological Engineering and Computing.

[10]  S. Rutkove,et al.  Impact of skin-subcutaneous fat layer thickness on electrical impedance myography measurements: An initial assessment , 2007, Clinical Neurophysiology.

[11]  R. Pethig,et al.  Dielectric properties of body tissues. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[12]  Seward B Rutkove,et al.  Discriminating neurogenic from myopathic disease via measurement of muscle anisotropy , 2009, Muscle & nerve.

[13]  S. Rutkove Electrical impedance myography: Background, current state, and future directions , 2009, Muscle & nerve.

[14]  R. Roubenoff,et al.  Recent advances in the biology and therapy of muscle wasting , 2010, Annals of the New York Academy of Sciences.

[15]  David A. Schoenfeld,et al.  Electrical impedance myography to assess outcome in amyotrophic lateral sclerosis clinical trials , 2007, Clinical Neurophysiology.