Paper 1: Survey of Auditory Hazards in Power Stations and Their Evaluation in Terms of Hearing Conservation
暂无分享,去创建一个
Detailed noise surveys of twenty-one modern power stations indicated that the main sources were turbo-alternators and fuel pulverizing plant, with boiler feed pumps, fans of various types, and high-pressure steam valves and pipes as secondary sources. Furthermore, noise levels increased with increasing capacity of plant. The noise levels measured in certain locations in power stations exceeded recent hearing damage risk criteria and it is likely that, unless protected, exposed personnel will eventually suffer hearing damage. The exposed personnel may be divided into two groups: those such as fitters, cleaners, etc., who are only exposed intermittently and the unit control staff who are often exposed continuously for 8-hour periods for five days every week.The principal features of noise-induced hearing loss and of a hearing conservation programme are outlined. The first steps are reduction of noise at source and in transmission; in the situations described, provision of acoustically isolated control rooms...
[1] K. D. Kryter. Effects of Ear Protective Devices on the Intelligibility of Speech in Noise , 1946 .
[2] C. G. Rice,et al. Earplugs and impaired hearing , 1966 .
[3] W. D. Ward,et al. Damage risk criteria and noise-induced hearing loss. , 1961, Archives of otolaryngology.