Reliability, validity, and clinical usability of a digital goniometer.

OBJECTIVE The purposes of this study were to establish the validity of a digital goniometer (DG) prototype, determine the inter- and intra-rater reliability of the DG as compared to the universal goniometer (UG), and evaluate and describe the clinical usability of the DG as a measurement tool. PARTICIPANTS Eighteen healthy patient models and 5 physical therapists volunteered to participate. METHODS Reliability testing of both the UG and DG was determined from the measurements of 5 therapists who performed 2 randomized, repeated measures of 5 joint motions on each of 6 patient models during 3 data collection sessions. To determine the validity of the DG, the investigators measured 8 randomly selected, computer-aided design (CAD) angles during each of the 3 data collection sessions. Physical therapist participants completed pre-/post-surveys to assess perceptions of clinical usability of the DG. RESULTS No statistically significant differences were found between devices. Comparison of the DG and UG demonstrated no difference for intra- or inter-rater reliability, with the DG yielding higher inter-rater ICC values for each of the 5 motions measured. CONCLUSIONS The DG has adequate concurrent criterion-related validity as a tool for assessment of joint ROM and equivalent inter- and intra-rater reliability to the UG. User surveys indicated that several of the novel features of the DG contributed to a higher likelihood that the device would be utilized by clinicians.

[1]  D. Urban,et al.  Intertester reliability and concurrent validity of fluid-based and universal goniometers for active knee flexion. , 1988, Physical therapy.

[2]  L. Brosseau,et al.  Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions. , 2001, Archives of physical medicine and rehabilitation.

[3]  S. Rose,et al.  Reliability and validity of goniometric measurements at the knee. , 1987, Physical therapy.

[4]  W Kowsuwon,et al.  Axial Rotation Gravity Goniometer: A Simple Design of Instrument and a Controlled Reliability Study , 1990, Clinical orthopaedics and related research.

[5]  Richard W. Bohannon,et al.  Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity. , 1987, Physical therapy.

[6]  R L Lamb,et al.  Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting. , 1991, Physical therapy.

[7]  A. Armstrong,et al.  Reliability of range-of-motion measurement in the elbow and forearm. , 1998, Journal of shoulder and elbow surgery.

[8]  D. R. Fish,et al.  Sources of goniometric error at the elbow. , 1985, Physical therapy.

[9]  Mark S. Young,et al.  Kodak's Ergonomic Design for People at Work , 2009 .

[10]  J M Rothstein,et al.  Goniometric reliability in a clinical setting. Shoulder measurements. , 1987, Physical therapy.

[11]  J. R. Landis,et al.  The measurement of observer agreement for categorical data. , 1977, Biometrics.

[12]  S. G. Feinberg,et al.  The role of usability testing and documentation in medical device safety , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  M. Eliasziw,et al.  Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example. , 1994, Physical therapy.

[14]  S L Wolf,et al.  Comparison of the reliability of the Orthoranger and the standard goniometer for assessing active lower extremity range of motion. , 1988, Physical therapy.

[15]  L. Portney,et al.  Foundations of Clinical Research , 1993 .

[16]  G. Murrell,et al.  Reliability of five methods for assessing shoulder range of motion. , 2001, The Australian journal of physiotherapy.

[17]  PD Dr. Werner Müller,et al.  The Knee , 1982, Springer Berlin Heidelberg.

[18]  J. M. Rothstein,et al.  Goniometric Reliability in a Clinical Setting , 1983 .

[19]  J M Rothstein,et al.  Goniometric reliability in a clinical setting. Elbow and knee measurements. , 1984, Physical therapy.

[20]  S. Azen,et al.  Reliability of goniometric measurements. , 1978, Physical therapy.

[21]  J. Plewes,et al.  Measurement of joint motion: A guide to goniometry , 1986 .

[22]  J. J. Gerhardt,et al.  Goniometric techniques for range-of-motion assessment. , 2001, Physical medicine and rehabilitation clinics of North America.

[23]  Vello Hein Comparison of a New Linear Instrument and the Gravity Goniometer for Assessing Knee Extension ROM among Children , 1998 .

[24]  D L Morgan,et al.  Practical Strategies for Combining Qualitative and Quantitative Methods: Applications to Health Research , 1998, Qualitative health research.

[25]  A R Smith,et al.  Modification of the long-armed goniometer. , 1978, Physical therapy.

[26]  B M Chesworth,et al.  Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation. , 1999, Journal of hand therapy : official journal of the American Society of Hand Therapists.