Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study.

BACKGROUND Successful hip reconstruction to restore the normal hip biomechanics requires precise placement of implants. Computer assisted navigation in total hip arthroplasty has been proposed to have the potential to help achieve a high accuracy in implant placement. The goal of the study was to evaluate the accuracy of an imageless computer navigation system on cadavers and to validate a non-invasive computed tomography method for post-operative determination of acetabular cup orientation. METHODS Total hip arthroplasty was performed on seven cadaver hips with the aid of an imageless computer navigation system. The achieved cup orientation were recorded using three methods, (1) intra-operatively using the imageless computer navigation system, (2) post-operatively with direct bone digitization and (3) with a computed tomography based three dimensional model interpreted by three raters. Measurement from the direct bone digitization was taken as the gold standard to evaluate the other two methods. The intra-rater and inter-rater consistency of the computer tomography-model method were assessed by Cronbach's alpha determination. FINDINGS Compared with the cup orientation obtained from the direct bone digitization, the average difference for anteversion and abduction were 3.3 (3.5) degrees (P=0.045) and 0.6 (3.7) degrees , respectively, for navigation reading. The average differences for computer tomography-model for three raters were 0.5 (2.1) degrees , 0.8 (1.5) degrees and 3.2 (3.3) degrees (P=0.043) for anteversion and 0.4 (1.6) degrees , 0.3 (1.6) degrees and 2.1 (2.7) degrees for abduction. The intra-rater consistency ranged from 0.626 for a novice rater to over 0.97 for experience raters. The inter-rater consistency (including novice and experienced raters) was over 0.90. INTERPRETATION While the values for cup orientation determined with imageless computer navigation were comparable to those from direct bone and implant digitization, the measurement for anteversion obtained was not as accurate as that for abduction. The proposed computer tomography-model method has an excellent intra-rater consistency for experienced raters, as well as an excellent overall inter-rater consistency. The study confirms that a non-invasive computed tomography based model analysis can be used in clinical practice as a valid method for post-operatively evaluating the orientation of the acetabular component.

[1]  J. Lewis,et al.  Dislocations after total hip-replacement arthroplasties. , 1978, The Journal of bone and joint surgery. American volume.

[2]  M. Krismer,et al.  Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. , 2005, The Journal of bone and joint surgery. British volume.

[3]  Karl-Heinz Widmer,et al.  A simplified method to determine acetabular cup anteversion from plain radiographs. , 2004, The Journal of arthroplasty.

[4]  D. D’Lima,et al.  The Effect of the Orientation of the Acetabular and Femoral Components on the Range of Motion of the Hip at Different Head-Neck Ratios* , 2000, The Journal of bone and joint surgery. American volume.

[5]  S. Kelley,et al.  The Influence of Patient-Related Factors and the Position of the Acetabular Component on the Rate of Dislocation after Total Hip Replacement* , 1997, The Journal of bone and joint surgery. American volume.

[6]  Hartmuth Kiefer,et al.  OrthoPilot cup navigation--how to optimise cup positioning? , 2003, International orthopaedics.

[7]  Rolf G. Haaker,et al.  Computerassistierte Hüftpfannennavigation bei primär- und sekundär dysplastischen Ausgangssituationen , 2003 .

[8]  D. Murray The definition and measurement of acetabular orientation. , 1993, The Journal of bone and joint surgery. British volume.

[9]  J. Visser,et al.  A new method for measuring angles after total hip arthroplasty. A study of the acetabular cup and femoral component. , 1981, The Journal of bone and joint surgery. British volume.

[10]  B. Jaramaz,et al.  Computer Assisted Orthopaedic Surgery: Image Guided and Robotic Assistive Technologies , 1998, Clinical orthopaedics and related research.

[11]  Guoyan Zheng,et al.  C-arm based navigation in total hip arthroplasty-background and clinical experience. , 2004, Injury.

[12]  J P Conaty,et al.  Classification and treatment of dislocations of total hip arthroplasty. , 1983, Clinical orthopaedics and related research.

[13]  D. McCollum,et al.  Dislocation after total hip arthroplasty. Causes and prevention. , 1990, Clinical orthopaedics and related research.

[14]  A. Duquennoy,et al.  CAUSES OF DISLOCATION OF TOTAL HIP ARTHROPLASTY , 1994 .

[15]  Dean D. Newton,et al.  Development of imageless computer navigation for acetabular component position in total hip replacement. , 2005, The Iowa orthopaedic journal.

[16]  F. Kummer,et al.  The effect of acetabular cup orientations on limiting hip rotation. , 1999, The Journal of arthroplasty.

[17]  R. Steffen,et al.  The accuracy of free-hand cup positioning - a CT based measurement of cup placement in 105 total hip arthroplasties , 2004, International Orthopaedics.

[18]  Stefan Klima,et al.  CT-based and fluoroscopy-based navigation for cup implantation in total hip arthroplasty (THA). , 2003, Surgical technology international.

[19]  J Grifka,et al.  Genauigkeit eines bildfreien Navigationssystemes für die Hüftpfannenimplantation – eine anatomische Studie / Accuracy of an Image-free Cup Navigation System – an Anatomical Study , 2004, Biomedizinische Technik. Biomedical engineering.

[20]  B F Morrey,et al.  Operative correction of an unstable total hip arthroplasty. , 1992, The Journal of bone and joint surgery. American volume.

[21]  P. Dicesare,et al.  Instability following total hip arthroplasty. , 2003, American journal of orthopedics.

[22]  B. Jaramaz,et al.  Computer Assisted Measurement of Cup Placement in Total Hip Replacement , 1998, Clinical orthopaedics and related research.

[23]  B. Morrey,et al.  Effects of acetabular abduction on cup wear rates in total hip arthroplasty. , 1998, The Journal of arthroplasty.

[24]  Guoyan Zheng,et al.  A hybrid CT-free navigation system for total hip arthroplasty. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[25]  K. Soffe,et al.  Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. , 1998, The Journal of arthroplasty.

[26]  Branislav Jaramaz,et al.  Computer-assisted orthopaedic surgery: minimally invasive hip and knee reconstruction. , 2004, The Orthopedic clinics of North America.

[27]  M Tingart,et al.  Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? , 2006, The Journal of bone and joint surgery. British volume.

[28]  Michael Nogler,et al.  Reduced Variability of Acetabular Cup Positioning with Use of an Imageless Navigation System , 2004, Clinical orthopaedics and related research.

[29]  B. Jolles,et al.  Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. , 2002, The Journal of arthroplasty.

[30]  D. Vandevelde,et al.  Reduction in variability of acetabular cup abduction using computer assisted surgery: a prospective and randomized study. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[31]  R. Barrack,et al.  Dislocation After Total Hip Arthroplasty: Implant Design and Orientation , 2003, The Journal of the American Academy of Orthopaedic Surgeons.

[32]  M Stockheim,et al.  [Computer-assisted navigated cup placement in primary and secondary dysplastic hips]. , 2003, Zeitschrift fur Orthopadie und ihre Grenzgebiete.

[33]  Branislav Jaramaz,et al.  Comparison of a mechanical acetabular alignment guide with computer placement of the socket. , 2002, The Journal of arthroplasty.