Observability enhancement by optimal PMU placement considering random power system outages

This paper enhances the observability of power networks by taking into consideration random component outages. The architecture of wide-area measurement system (WAMS) is analyzed in order to identify components that would affect the network observability. An iterative framework is devised to calculate a bus index in power networks equipped with phasor measurement units (PMUs) and conventional measurements. The average of bus indices represents a system index which provides an overall insight on the power network observability. The system index is utilized as a criterion to distinguish among multiple optimal PMU placements. Conventional bus injection and line flow measurements and the effect of zero-injection buses are considered in the proposed model. The numerical analyses are carried out for the proposed model and the results are discussed in detail.

[1]  Joong-Rin Shin,et al.  Optimal placement of phasor measurement units with GPS receiver , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[2]  A. Abur,et al.  Observability analysis and measurement placement for systems with PMUs , 2004, IEEE PES Power Systems Conference and Exposition, 2004..

[3]  A.M. Ranjbar,et al.  Optimal Placement of Phasor Measurement Units: Particle Swarm Optimization Approach , 2007, 2007 International Conference on Intelligent Systems Applications to Power Systems.

[4]  B. Gou Optimal Placement of PMUs by Integer Linear Programming , 2008, IEEE Transactions on Power Systems.

[5]  Farrokh Aminifar,et al.  Reliability Modeling of PMUs Using Fuzzy Sets , 2010, IEEE Transactions on Power Delivery.

[6]  Demetrios G. Eliades,et al.  Placement of Synchronized Measurements for Power System Observability , 2009, IEEE Transactions on Power Delivery.

[7]  Roy Billinton,et al.  Reliability evaluation of engineering systems : concepts and techniques , 1992 .

[8]  Yang Wang,et al.  Evaluating multiple reliability indices of regional networks in wide area measurement system , 2009 .

[9]  Mohammad Shahidehpour,et al.  Impact of Security on Power Systems Operation , 2005, Proceedings of the IEEE.

[10]  M. Hemmingsson,et al.  Wide area system monitoring and control - terminology, phenomena, and solution implementation strategies , 2004, IEEE Power and Energy Magazine.

[11]  M. Shahidehpour,et al.  Contingency-Constrained PMU Placement in Power Networks , 2010, IEEE Transactions on Power Systems.

[12]  A. Abur,et al.  Placement of PMUs to Enable Bad Data Detection in State Estimation , 2006, IEEE Transactions on Power Systems.

[13]  M. Begovic,et al.  Nondominated sorting genetic algorithm for optimal phasor measurement placement , 2002, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[14]  Christian Rehtanz,et al.  Design Aspects for Wide-Area Monitoring and Control Systems , 2005, Proceedings of the IEEE.

[15]  Suttichai Premrudeepreechacharn,et al.  An Optimal PMU Placement Method Against Measurement Loss and Branch Outage , 2007 .

[16]  B. Gou,et al.  Generalized Integer Linear Programming Formulation for Optimal PMU Placement , 2008, IEEE Transactions on Power Systems.

[17]  S.A. Soman,et al.  Optimal Multistage Scheduling of PMU Placement: An ILP Approach , 2008, IEEE Transactions on Power Delivery.

[18]  F. J. Marín,et al.  Genetic algorithms for optimal placement of phasor measurement units in electrical networks , 2003 .

[19]  M. Begovic,et al.  Nondominated Sorting Genetic Algorithm for Optimal Phasor Maesurement Placement , 2002 .

[20]  E. Kyriakides,et al.  Measurement Uncertainty Considerations in Optimal Sensor Deployment for State Estimation , 2007, 2007 IEEE International Symposium on Intelligent Signal Processing.

[21]  M. Fotuhi-Firuzabad,et al.  Optimal Placement of Phasor Measurement Units Using Immunity Genetic Algorithm , 2009, IEEE Transactions on Power Delivery.

[22]  Chunhua Peng,et al.  A hybrid algorithm based on BPSO and immune mechanism for PMU optimization placement , 2008, 2008 7th World Congress on Intelligent Control and Automation.

[23]  G. Heydt,et al.  The Measurement Outage Table and State Estimation , 2008, IEEE Transactions on Power Systems.

[24]  Matt Donnelly,et al.  Eastern Interconnection Phasor Project , 2006, Proceedings of the 39th Annual Hawaii International Conference on System Sciences (HICSS'06).

[25]  Yuanzhan Sun,et al.  Optimal PMU placement for full network observability using Tabu search algorithm , 2006 .

[26]  E. Kyriakides,et al.  Optimal Placement of Phasor Measurement Units for Power System Observability , 2008, IEEE Transactions on Power Systems.

[27]  Arun G. Phadke,et al.  Synchronized Phasor Measurements and Their Applications , 2008 .

[28]  T. Baldwin,et al.  Power system observability with minimal phasor measurement placement , 1993 .

[29]  A.G. Phadke,et al.  HISTORY AND APPLICATIONS OF PHASOR MEASUREMENTS , 2006, 2006 IEEE PES Power Systems Conference and Exposition.