Synchronised data-based adaptive backup protection for series compensated line

Metal oxide varistor (MOV) protected series capacitor, when present in a fault loop, modulates the impedance seen by the relay. With series capacitor placed away from the relay, the information on the level of compensation is required for proper protection decision by distance relay. In this study, synchronised data obtained at both ends are applied to calculate the compensation level which is used to adapt the relay setting for backup protection of adjacent line. The mutual coupling in the compensation portion is also considered in the apparent impedance computation. The status of capacitor during fault (bypassed or not) is obtained through impedance calculation during fault and the relay setting is adapted accordingly. Using data simulated through EMTDC/PSCAD for a series compensated line the technique is tested and found to be accurate.

[1]  A. T. Johns,et al.  Performance of an adaptive protection scheme for series compensated EHV transmission systems using neural networks , 1996 .

[2]  James S. Thorp,et al.  Synchronized Phasor Measurement Applications in Power Systems , 2010, IEEE Transactions on Smart Grid.

[3]  T.S. Sidhu,et al.  A new approach for calculating zone-2 setting of distance relays and its use in an adaptive protection system , 2004, IEEE Transactions on Power Delivery.

[4]  A. K. David,et al.  Adaptive relay setting for stand-alone digital distance protection , 1994 .

[5]  Syed Nasar,et al.  Electric Power Systems , 1972 .

[6]  M.M. Saha,et al.  Adaptive distance protection for series compensated transmission lines , 2004, 2004 IEEE/PES Transmision and Distribution Conference and Exposition: Latin America (IEEE Cat. No. 04EX956).

[7]  A. K. Pradhan,et al.  Apply PMU data for Zone-2 setting of series compensated line , 2011, 2011 International Conference on Energy, Automation and Signal.

[8]  A.I. Megahed,et al.  Usage of wavelet transform in the protection of series-compensated transmission lines , 2006, IEEE Transactions on Power Delivery.

[9]  Daniel L. Goldsworthy A Linearized Model for Mov-Protected Series Capacitors , 1987, IEEE Transactions on Power Systems.

[10]  A. T. Johns,et al.  A novel non-unit protection for series compensated EHV transmission lines based on fault generated high frequency voltage signals , 1998 .

[11]  Davis Erwin,et al.  PG&E 500 kV series-compensated transmission line relay replacement: Design requirements and RTDS® testing , 2011, 2011 64th Annual Conference for Protective Relay Engineers.