Reconstruction of super-resolution lung 4D-CT using patch-based sparse representation

4D-CT plays an important role in lung cancer treatment. However, due to the inherent high-dose exposure associated with CT, dense sampling along superior-inferior direction is often not practical. As a result, artifacts such as lung vessel discontinuity and partial volume are typical in 4D-CT images and might mislead dose administration in radiation therapy. In this paper, we present a novel patch-based technique for super-resolution enhancement of the 4D-CT images along the superior-inferior direction. Our working premise is that the anatomical information that is missing at one particular phase can be recovered from other phases. Based on this assumption, we employ a patch-based mechanism for guided reconstruction of super-resolution axial slices. Specifically, to reconstruct each targeted super-resolution slice for a CT image at a particular phase, we agglomerate a dictionary of patches from images of all other phases in the 4D-CT sequence. Then we perform a sparse combination of the patches in this dictionary to reconstruct details of a super-resolution patch, under constraint of similarity to the corresponding patches in the neighboring slices. By iterating this procedure over all possible patch locations, a superresolution 4D-CT image sequence with enhanced anatomical details can be eventually reconstructed. Our method was extensively evaluated using a public dataset. In all experiments, our method outperforms the conventional linear and cubic-spline interpolation methods in terms of preserving image details and suppressing misleading artifacts.

[1]  Hideki Yoshikawa,et al.  Automated segmentation of acetabulum and femoral head from 3-d CT images , 2003, IEEE Transactions on Information Technology in Biomedicine.

[2]  Steve B. Jiang,et al.  4D CT sorting based on patient internal anatomy , 2009, Physics in medicine and biology.

[3]  Zongben Xu,et al.  Image Inpainting by Patch Propagation Using Patch Sparsity , 2010, IEEE Transactions on Image Processing.

[4]  A. Boyer,et al.  Radiation dose reduction in four-dimensional computed tomography. , 2005, Medical physics.

[5]  Peter Balter,et al.  The use of 4DCT to reduce lung dose: a dosimetric analysis. , 2009, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[6]  A. Bruckstein,et al.  K-SVD : An Algorithm for Designing of Overcomplete Dictionaries for Sparse Representation , 2005 .

[7]  M. Elad,et al.  $rm K$-SVD: An Algorithm for Designing Overcomplete Dictionaries for Sparse Representation , 2006, IEEE Transactions on Signal Processing.

[8]  Thomas S. Huang,et al.  Image Super-Resolution Via Sparse Representation , 2010, IEEE Transactions on Image Processing.

[9]  Michael Elad,et al.  Sparse Representation for Color Image Restoration , 2008, IEEE Transactions on Image Processing.

[10]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[11]  R. Keys Cubic convolution interpolation for digital image processing , 1981 .

[12]  S T Roweis,et al.  Nonlinear dimensionality reduction by locally linear embedding. , 2000, Science.

[13]  Robert Pless,et al.  Manifold learning for 4D CT reconstruction of the lung , 2008, 2008 IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops.

[14]  R. Castillo,et al.  A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets , 2009, Physics in medicine and biology.

[15]  Radhe Mohan,et al.  Four-dimensional computed tomography-based treatment planning for intensity-modulated radiation therapy and proton therapy for distal esophageal cancer. , 2008, International journal of radiation oncology, biology, physics.

[16]  Michael Elad,et al.  Image Denoising Via Sparse and Redundant Representations Over Learned Dictionaries , 2006, IEEE Transactions on Image Processing.

[17]  M. Unser,et al.  Interpolation revisited [medical images application] , 2000, IEEE Transactions on Medical Imaging.

[18]  S. Mallat,et al.  Adaptive greedy approximations , 1997 .