A Smart Frequency Domain-Based Modeling Procedure of Rogowski Coil for Power Systems Applications

Rogowski coils are key measurement instruments in several applications due to their flexibility, large bandwidth, linearity, and so on. Like the majority of the instrument transformers (ITs), Rogowski coils are standardized and their use is regulated almost for every application. This article focuses on a smart way for the equivalent parameters’ computation of the Rogowski coil. The parameter computation is performed by evaluating the Rogowski response when subjected to a single waveform generated to fulfill a specific requirement on its frequency content. Results demonstrate the equivalency of the presented method compared to the typical frequency sweep test. In addition, the results have been used to validate Rogowski’s output estimate procedure presented by the authors in a previous work.

[1]  W. Collett,et al.  Electromagnetic Modeling of a High Voltage Current Transformer , 2007, 2007 39th North American Power Symposium.

[2]  Lorenzo Peretto,et al.  A Simple Modelling Procedure of Rogowski Coil for Power Systems Applications , 2019, 2019 IEEE 10th International Workshop on Applied Measurements for Power Systems (AMPS).

[3]  Akira Nakagawa,et al.  Dynamic impulse response model for nonlinear acoustic system and its application to acoustic echo canceller , 2009, 2009 IEEE Workshop on Applications of Signal Processing to Audio and Acoustics.

[4]  Karel Draxler,et al.  Calibration of instrument current transformers at low currents using lock-in amplifier , 2017, 2017 International Conference on Applied Electronics (AE).

[5]  Antonio Cataliotti,et al.  Metrological performances of voltage and current instrument transformers in harmonics measurements , 2018, 2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[6]  Lorenzo Peretto,et al.  Effect of temperature on the accuracy of inductive current transformers , 2018, 2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[7]  Z. C. Wang,et al.  Frequency response analysis of a Rogowski coil transducer for railgun pulse current measurement , 2015, 2015 IEEE Pulsed Power Conference (PPC).

[8]  T. Qian,et al.  Study on Nanosecond Impulse Frequency Response for Detecting Transformer Winding Deformation Based on Morlet Wavelet Transform , 2018, 2018 International Conference on Power System Technology (POWERCON).

[9]  Lorenzo Peretto,et al.  Low power voltage transformer accuracy class effects on the residual voltage measurement , 2018, 2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[10]  Steve Mitchell,et al.  Online monitoring of power transformers using impulse frequency response analysis , 2017, 2017 Iranian Conference on Electrical Engineering (ICEE).

[11]  Zhang Zhou Sheng,et al.  The analysis of the factors affecting the performance of Clamp Rogowski coil , 2014, 2014 International Conference on Power System Technology.

[12]  A. Abu-Siada,et al.  A New Online Temperature Compensation Technique for Electronic Instrument Transformers , 2019, IEEE Access.

[13]  A. Elhaffar,et al.  High Frequency Current Transformer Modeling for Traveling Waves Detection , 2007, 2007 IEEE Power Engineering Society General Meeting.

[14]  Lin Du,et al.  Study on the impulse characteristics of capacitive voltage transformer , 2013, 2013 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices.

[15]  Branislav Djokic,et al.  Hydro-generator sudden short-circuit testing using Rogowski coils , 2016, 2016 Conference on Precision Electromagnetic Measurements (CPEM 2016).

[16]  I. A. Metwally,et al.  Performance Improvement of Slow-Wave Rogowski Coils for High Impulse Current Measurement , 2013, IEEE Sensors Journal.

[17]  Guixin Zhang,et al.  Planar Rogowski Coil Current Transducer Used for Three-phase Plate-form Busbars , 2007, 2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007.

[18]  Mario Chiampi,et al.  Evaluation of Flexible Rogowski Coil Performances in Power Frequency Applications , 2011, IEEE Transactions on Instrumentation and Measurement.

[19]  P. Schegner,et al.  A model to compute the resonance effects in high current instrument transformers , 2017, 2017 IEEE International Magnetics Conference (INTERMAG).

[20]  Z. Kolodziejczyk,et al.  Novel autonomous voltage and current measurement unit for Smart Grids , 2012, International Symposium on Power Electronics Power Electronics, Electrical Drives, Automation and Motion.

[21]  Antonello Monti,et al.  Calibration of Synchronized Measurement System: from the Instrument Transformer to the PMU , 2018, 2018 IEEE 9th International Workshop on Applied Measurements for Power Systems (AMPS).

[22]  V. Premalatha,et al.  Instrument transformer winding fault analysis using frequency response analysis , 2012, 2012 IEEE International Conference on Advanced Communication Control and Computing Technologies (ICACCCT).

[23]  Udaya Kumar Performance of Rogowski coils at higher frequencies , 2010, 2010 30th International Conference on Lightning Protection (ICLP).

[24]  Lorenzo Peretto,et al.  Uncertainty sources analysis of a calibration system for the accuracy vs. temperature verification of voltage transformers , 2018, Journal of Physics: Conference Series.

[25]  Lorenzo Peretto,et al.  Performance evaluation of an energy meter for low-voltage system monitoring , 2018, Journal of Physics: Conference Series.

[26]  Peerawut Yutthagowith,et al.  Rogowski coil with an active integrator for measurement of switching impulse current , 2013, 2013 10th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology.

[27]  J. Hallstrom,et al.  On-site calibration of a current transformer using a Rogowski coil , 2008, 2008 Conference on Precision Electromagnetic Measurements Digest.

[28]  Lorenzo Peretto,et al.  Assessment of Metrological Characteristics of Calibration Systems for Accuracy vs. Temperature Verification of Voltage Transformer , 2017, 2017 IEEE International Workshop on Applied Measurements for Power Systems (AMPS).

[29]  Roberto Ottoboni,et al.  Instrument transformers: A different approach to their modeling , 2011, 2011 IEEE International Workshop on Applied Measurements for Power Systems (AMPS).

[30]  Lorenzo Peretto,et al.  Traceability of Low-Power Voltage Transformer for Medium Voltage Application , 2014, IEEE Transactions on Instrumentation and Measurement.

[31]  F. P. Espino-Cortes,et al.  Electric stress grading on bushings of combined instrument transformers using high permittivity polymeric composites , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[32]  V. Jayashankar,et al.  Instrument transformer performance under distorted-conditions , 2004, Proceedings of the IEEE INDICON 2004. First India Annual Conference, 2004..

[33]  Martin Dadić,et al.  FIR modeling of voltage instrument transformers from frequency response data , 2018, 2018 First International Colloquium on Smart Grid Metrology (SmaGriMet).