A flexible biosensor for glucose

A flexible glucose biosensor was constructed by immobilizing glucose oxidase within a gold-coated, hydrophilic polytetrafluoroethylene membrane. All reagents and materials used were harmless and nontoxic. Enzyme immobilization was improved using a mesh mask during gold deposition, the grid pattern permitting better access into the membrane. The masked sensors had greatly improved output currents and linearity. The sensor was linear up to 662 mgL−1, the range covering the concentrations encountered in normal and diabetic human tear fluids. The current was proportional to the square of the electrode area, hence an electrode of known dimensions can be used without precalibration. Sterilization using 80% ethanol had a negligible effect on its response. The sensor is well suited to the detection of glucose or other analytes in body fluids, such as tears, airway mucus, sweat, and saliva.

[1]  Isao Karube,et al.  Analysis of metabolites in sweat as a measure of physical condition , 1994 .

[2]  Kenji Yokoyama,et al.  Flexible conductometric sensor , 1993 .

[3]  Norman F. Sheppard,et al.  Electrical conductivity measurements using microfabricated interdigitated electrodes , 1993 .

[4]  Christopher R. Lowe,et al.  Multi-analyte miniature conductance biosensor , 1990 .

[5]  W. Hugo,et al.  The effect of chlorhexidine on the electrophoretic mobility, cytoplasmic constituents, dehydrogenase activity and cell walls of Escherichia coli and Staphylococcus aureus , 1966, The Journal of pharmacy and pharmacology.

[6]  Toshihide Kuriyama,et al.  A lift-off method for patterning enzyme-immobilized membranes in multi-biosensors , 1988 .

[7]  Hiroaki Suzuki,et al.  Micromachined Clark oxygen electrode , 1993 .

[8]  J. Gatzy,et al.  Regional differences in airway surface liquid composition. , 1981, Journal of applied physiology: respiratory, environmental and exercise physiology.

[9]  I. Karube,et al.  Ultramicro acetylcholine sensor based on an enzyme-modified carbon fibre electrode , 1991 .

[10]  G. K. Adams,et al.  Effects of temperature, relative humidity, and mode of breathing on canine airway secretions. , 1979, Journal of applied physiology: respiratory, environmental and exercise physiology.

[11]  Edward S. Kolesar,et al.  Interdigitated gate electrode field effect transistor for the selective detection of nitrogen dioxide and diisopropyl methylphosphonate , 1989 .

[12]  D K Sen,et al.  Tear glucose levels in normal people and in diabetic patients. , 1980, The British journal of ophthalmology.

[13]  M. Neuman,et al.  Sensor for measuring surface fluid conductivity in vivo , 1988, IEEE Transactions on Biomedical Engineering.

[14]  Jun Kimura,et al.  An integrated SOS/FET multi-biosensor , 1986 .