Total liquid ventilation: a new approach to improve 3D OCT image quality of alveolar structures in lung tissue.

Little is known about mechanical processes of alveolar tissue during mechanical ventilation. Optical coherence tomography (OCT) as a three-dimensional and high-resolution imaging modality can be used to visualize subpleural alveoli during artificial ventilation. The quality of OCT images can be increased by matching the refractive index inside the alveoli to the one of tissue via liquid-filling. Thereby, scattering loss can be decreased and higher penetration depth and tissue contrast can be achieved. We show the liquid-filling of alveolar structures verified by optical coherence tomography and intravital microscopy (IVM) and the advantages of index matching for OCT imaging of subpleural alveoli in a mouse model using a custom-made liquid ventilator.

[1]  T A Wilson,et al.  A model for mechanical structure of the alveolar duct. , 1982, Journal of applied physiology: respiratory, environmental and exercise physiology.

[2]  Thomas H Shaffer,et al.  Fluorocarbon Ventilation: Maximal Expiratory Flows and CO2 Elimination , 1988, Pediatric Research.

[3]  Peter Gehr,et al.  Pulmonary surfactant: Surface properties and function of alveolar and airway surfactant , 1992 .

[4]  松田 兼一 Effect of ventilatory variables on gas exchange and hemodynamics during total liquid ventilation in a rat model , 2004 .

[5]  H. Colt,et al.  Two-dimensional and 3-dimensional optical coherence tomographic imaging of the airway, lung, and pleura. , 2005, The Journal of thoracic and cardiovascular surgery.

[6]  Y. Li,et al.  The FASEB Journal • Research Communication Control of APP processing and A � generation level by , 2022 .

[7]  Wolfgang M Kuebler,et al.  Intravital microscopy of the murine pulmonary microcirculation. , 2008, Journal of applied physiology.

[8]  Edmund Koch,et al.  Improved three-dimensional Fourier domain optical coherence tomography by index matching in alveolar structures. , 2009, Journal of biomedical optics.

[9]  Edmund Koch,et al.  Simultaneous three-dimensional optical coherence tomography and intravital microscopy for imaging subpleural pulmonary alveoli in isolated rabbit lungs. , 2009, Journal of biomedical optics.

[10]  David D Sampson,et al.  In situ imaging of lung alveoli with an optical coherence tomography needle probe. , 2011, Journal of biomedical optics.

[11]  Edmund Koch,et al.  Intravital microscopy of subpleural alveoli via transthoracic endoscopy. , 2011, Journal of biomedical optics.

[12]  Carolin I Unglert,et al.  Evaluation of optical reflectance techniques for imaging of alveolar structure , 2012, Journal of biomedical optics.