A direct-infusion- and HPLC-ESI-Orbitrap-MS approach for the characterization of intact PEGylated proteins.

The characterization of proteins modified with poly(ethylene glycol) (PEG), such as recombinant human granulocyte-colony stimulating factor (PEGylated rhG-CSF or pegfilgrastim), by electrospray ionization-mass spectrometry (ESI-MS) constitutes a challenge due to the overlapping protein charge state pattern and PEG polydispersity. In order to minimize spectral overlaps, charge reduction by means of the addition of amine was applied. Method development for direct-infusion measurements, carried out on an ESI-time-of-flight (ESI-TOF) instrument, demonstrated the potential of triethylamine (TEA) for shifting the charge state pattern toward lower-charged species and of formic acid (FA) for causing higher charging. After successful method transfer to the LTQ Orbitrap XL instrument, isotopically resolved mass spectra could be acquired. With a median mass accuracy of 1.26 ppm, a number-average monoisotopic molecular mass of 40074.64 Da was determined for pegfilgrastim. The direct comparison of three Orbitrap mass spectrometers, namely the LTQ Orbitrap XL, the Exactive, and the Q Exactive, demonstrated that online interfacing to high performance liquid chromatography (HPLC) was only feasible with the Q Exactive, which offers adequate spectral quality on a time scale compatible with chromatographic separation (i.e., 0.2 min acquisition time per chromatographic peak). Finally, the applicability of both direct-infusion Orbitrap MS and HPLC interfaced to Orbitrap MS was demonstrated for the detection of methionine oxidation in pegfilgrastim. Singly, doubly, and triply oxidized species were readily resolved in the chromatogram, while their oxidation status was easily determined from the mass shifts observed in the deconvoluted mass spectra.

[1]  Kang-Choon Lee,et al.  Isolation, Characterization, and Stability of Positional Isomers of Mono-PEGylated Salmon Calcitonins , 1999, Pharmaceutical Research.

[2]  J. Malmstrøm Characterization of 40 kDa poly(ethylene glycol) polymers by proton transfer reaction QTOF mass spectrometry and 1H-NMR spectroscopy , 2012, Analytical and Bioanalytical Chemistry.

[3]  P. Caliceti,et al.  New PEGs for peptide and protein modification, suitable for identification of the PEGylation site. , 2001, Bioconjugate chemistry.

[4]  D. Suckau,et al.  Toward top-down determination of PEGylation site using MALDI in-source decay MS analysis , 2009, Journal of the American Society for Mass Spectrometry.

[5]  Ryan D Leib,et al.  Enhanced mixture analysis of poly(ethylene glycol) using high-field asymmetric waveform ion mobility spectrometry combined with fourier transform ion cyclotron resonance mass spectrometry. , 2006, Analytical chemistry.

[6]  M. Mann,et al.  Ultra High Resolution Linear Ion Trap Orbitrap Mass Spectrometer (Orbitrap Elite) Facilitates Top Down LC MS/MS and Versatile Peptide Fragmentation Modes* , 2011, Molecular & Cellular Proteomics.

[7]  David S. Wishart,et al.  DrugBank: a knowledgebase for drugs, drug actions and drug targets , 2007, Nucleic Acids Res..

[8]  E. Gelpí From large analogical instruments to small digital black boxes: 40 years of progress in mass spectrometry and its role in proteomics. Part II 1985-2000. , 2009, Journal of Mass Spectrometry.

[9]  I. Kaltashov,et al.  Structural characterization of protein–polymer conjugates. I. Assessing heterogeneity of a small PEGylated protein and mapping conjugation sites using ion exchange chromatography and top-down tandem mass spectrometry , 2012 .

[10]  J. M. Harris,et al.  Effect of pegylation on pharmaceuticals , 2003, Nature Reviews Drug Discovery.

[11]  Lihua Huang,et al.  Characterization of poly(ethylene glycol) and PEGylated products by LC/MS with postcolumn addition of amines. , 2009, Analytical chemistry.

[12]  R. Zubarev,et al.  Approaches and Limits for Accurate Mass Characterization of Large Biomolecules , 1995 .

[13]  J. Abraham The international conference on harmonisation of technical requirements for registration of pharmaceuticals for human use , 2009 .

[14]  Bernhardt L Trout,et al.  Comparative oxidation studies of methionine residues reflect a structural effect on chemical kinetics in rhG-CSF. , 2006, Biochemistry.

[15]  Haeshin Lee,et al.  A novel method for identifying PEGylation sites of protein using biotinylated PEG derivatives. , 2003, Journal of Pharmacy and Science.

[16]  D. Isailovic,et al.  Resolving oligomers from fully grown polymers with IMS-MS. , 2007, Analytical chemistry.

[17]  Lihua Huang,et al.  Elucidation of PEGylation site with a combined approach of in-source fragmentation and CID MS/MS , 2010, Journal of the American Society for Mass Spectrometry.

[18]  P. Caliceti,et al.  Pharmacokinetic and biodistribution properties of poly(ethylene glycol)-protein conjugates. , 2003, Advanced drug delivery reviews.

[19]  D. Brems,et al.  Characterization and Stability of N-terminally PEGylated rhG-CSF , 1996, Pharmaceutical Research.

[20]  A. Makarov,et al.  Dynamics of ions of intact proteins in the Orbitrap mass analyzer , 2009, Journal of the American Society for Mass Spectrometry.

[21]  Robert J. Yokelson,et al.  VOC identification and inter-comparison from laboratory biomass burning using PTR-MS and PIT-MS , 2011 .

[22]  G. Walsh Second-generation biopharmaceuticals. , 2004, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[23]  C. Fenselau,et al.  A strategy for characterization of polyethylene glycol-derivatized proteins. A mass spectrometric analysis of the attachment sites in polyethylene glycol-derivatized superoxide dismutase. , 1993, Drug metabolism and disposition: the biological fate of chemicals.

[24]  P. Schnier,et al.  Gas-phase proton-transfer chemistry coupled with TOF mass spectrometry and ion mobility-MS for the facile analysis of poly(ethylene glycols) and PEGylated polypeptide conjugates. , 2008, Analytical chemistry.

[25]  G Shimamoto,et al.  Chemical modification and site-directed mutagenesis of methionine residues in recombinant human granulocyte colony-stimulating factor: effect on stability and biological activity. , 1999, Archives of biochemistry and biophysics.

[26]  L. M. Smith,et al.  Corona discharge in charge reduction electrospray mass spectrometry. , 2000, Analytical chemistry.

[27]  V. G. Berezkin,et al.  The essence of chromatography , 2002 .

[28]  Johann Holzmann,et al.  Top-down MS for rapid methionine oxidation site assignment in filgrastim , 2013, Analytical and Bioanalytical Chemistry.

[29]  G. Glish,et al.  Ion/molecule reactions to chemically deconvolute the electrospray ionization mass spectra of synthetic polymers. , 2006, Analytical chemistry.

[30]  A. Schacher,et al.  Isolation, structural characterization, and antiviral activity of positional isomers of monopegylated interferon alpha-2a (PEGASYS). , 2003, Protein expression and purification.

[31]  M. Bentley,et al.  Chemistry for peptide and protein PEGylation. , 2002, Advanced drug delivery reviews.

[32]  R. Heeren,et al.  Electrospray ionization mass spectrometry of the non-covalent complexes of ammonium ions with high molar mass polyethers , 2011 .

[33]  M. Mann,et al.  Interpreting mass spectra of multiply charged ions , 1989 .

[34]  M. Mann,et al.  Mass Spectrometry-based Proteomics Using Q Exactive, a High-performance Benchtop Quadrupole Orbitrap Mass Spectrometer* , 2011, Molecular & Cellular Proteomics.

[35]  M. Senko,et al.  Determination of monoisotopic masses and ion populations for large biomolecules from resolved isotopic distributions , 1995, Journal of the American Society for Mass Spectrometry.

[36]  W Wang,et al.  Instability, stabilization, and formulation of liquid protein pharmaceuticals. , 1999, International journal of pharmaceutics.