An investigation on climate responsive design strategies of vernacular housing in Vietnam

Energy conservation issues and environmental problems in recent years have increased interest in traditional architecture which is well known for its energy saving designs. This paper thoroughly investigates vernacular housing designs and evaluates on the aspect of building physics. A new research methodology which is adapted to the natural and social context of Vietnam was proposed and applied. The process was carried out step by step, including: climate zoning, systematic analysis, in-situ survey and building simulations. The results of this study indicate that vernacular housing in Vietnam is creatively adapted to the local natural conditions and uses various climate responsive strategies. Through this study, the most frequently used strategies and their effectiveness were derived. The authors also found that under extreme weather conditions, traditional designs might not be sufficient to maintain indoor thermal comfort.

[1]  Bjørn Berge,et al.  The Ecology of Building Materials , 2000 .

[2]  J. E. Janssen,et al.  Ventilation for acceptable indoor air quality , 1989 .

[3]  Ignacio Cañas,et al.  Recovery of Spanish vernacular construction as a model of bioclimatic architecture , 2004 .

[4]  Bruno Peuportier Bancs d'essais de logiciels de simulation thermique. , 2005 .

[5]  Kenichi Hasegawa,et al.  Passive cooling effect of traditional Japanese building's features , 2007 .

[6]  Helena Coch,et al.  Chapter 4--Bioclimatism in vernacular architecture , 1998 .

[7]  Kifle G. Gebremedhin,et al.  Characterization of flow field in a ventilated space and simulation of heat exchange between cows and their environment , 2003 .

[8]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[9]  A. Moret Rodrigues,et al.  Experimental and numerical study of wind pressures on irregular-plan shapes , 2005 .

[10]  J. Morel,et al.  Assessing the anisotropy of rammed earth , 2009 .

[11]  Gail Brager,et al.  Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55 , 2002 .

[12]  Zerrin Yilmaz,et al.  Energy efficient design strategies in the hot dry area of Turkey , 2008 .

[13]  T. Kubota,et al.  The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia , 2009 .

[14]  Anh Tuan Nguyen,et al.  The effect of ceiling configurations on indoor air motion and ventilation flow rates , 2011 .

[15]  A. Dili,et al.  Passive control methods of Kerala traditional architecture for a comfortable indoor environment: Comparative investigation during various periods of rainy season , 2010 .

[16]  P. Fanger,et al.  Extension of the PMV model to non-air-conditioned buildings in warm climates , 2002 .

[17]  Vissilia Anna-Maria,et al.  Evaluation of a sustainable Greek vernacular settlement and its landscape: Architectural typology and building physics , 2009 .

[18]  R. J. S. Spence,et al.  Building materials in developing countries , 1983 .

[19]  Helena Coch,et al.  Bioclimatism in vernacular architecture , 1998 .