Efficiency improvement in soft-switching three-level converters for high power UPS

Efficiency of high power Uninterruptible Power Supplies (UPS) is a fundamental criterion regarding the permanent use of such a device. A state of the art on soft-switching over constraint of the UPS application has been made. The principle of Auxiliary Resonant Commutated Pole (ARCP) using autotransformer has been identified as the most interesting way to increase efficiency or switching frequency. Its application for multi-level converters has been studied. A simplified resonant pole has been proposed for both three-level rectifier and inverter used in UPS. The design criteria have been discussed. A single phase of a 125 kVA three-level UPS has been realized and tested. The concept has been validated.

[1]  Bimal K. Bose,et al.  Power Electronics and Motor Drives Recent Progress and Perspective , 2009, IEEE Transactions on Industrial Electronics.

[2]  R.W. De Doncker,et al.  Design of a Flexible Control Platform for Soft-Switching Multilevel Inverters , 2007, IEEE Transactions on Power Electronics.

[3]  Thierry Meynard,et al.  Switching faults and safe control of an ARCP multicell flying capacitor inverter , 2003 .

[4]  I. Barbi,et al.  Control simplification and stress reduction in a modified PWM zero voltage switching pole inverter , 1999, APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285).

[5]  P.W. Wheeler,et al.  Comparison of losses in multilevel converters for aerospace applications , 2008, 2008 IEEE Power Electronics Specialists Conference.

[6]  Jose Renes Pinheiro,et al.  An active auxiliary commutation circuit for inverters , 1996, PESC Record. 27th Annual IEEE Power Electronics Specialists Conference.

[7]  Fang Z. Peng,et al.  Development and Test of a 260 kVA Inverter with a Passive Soft-Switching Snubber , 2007, APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition.

[8]  Dushan Boroyevich,et al.  A three-phase soft-transition inverter with a novel control strategy for zero-current and near zero-voltage switching , 2001 .

[9]  Jaime Arau,et al.  Two-Stage Uninterruptible Power Supply With High Power Factor , 2008, IEEE Transactions on Industrial Electronics.

[10]  Ivo Barbi,et al.  Zero-voltage switching for the neutral-point-clamped (NPC) inverter , 2002, IEEE Trans. Ind. Electron..

[11]  Philippe Delarue,et al.  A Simplified Resonant Pole for Three-Level Soft-Switching PFC Rectifier Used in UPS , 2010, IEEE Transactions on Industrial Electronics.

[12]  R.W. De Doncker,et al.  The auxiliary resonant commutated pole converter , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[13]  R.W. De Doncker,et al.  Design of a Flexible Control Platform for Soft-Switching Multi-Level Inverters , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.