Topology Optimization to reduce the stress shielding effect for orthopedic applications

Abstract Orthopedic problems are significantly increasing posing pressure to healthcare systems. Traditional clinical procedures for traumatic bone fracture applications comprise the use of high stiffness metallic implants caused by the built-up material and implant design. These implants show a high mechanical mismatch comparing to bone properties resulting in stress shielding phenomena that leads to less dense and fragile bone. This paper follows a design phase by exploring the use of 3D Topology Optimization to create lightweight metallic implants with reduced stiffness, thus minimising stress shielding and bone loss problems.

[1]  Hannu-Ville Leskelä,et al.  The mechanism of action of induced membranes in bone repair. , 2013, The Journal of bone and joint surgery. American volume.

[2]  A. Oryan,et al.  Basic concepts regarding fracture healing and the current options and future directions in managing bone fractures , 2015, International wound journal.

[3]  Jocelyn T. Compton,et al.  Optimal internal fixation of anatomically shaped synthetic bone grafts for massive segmental defects of long bones. , 2015, Clinical biomechanics.

[4]  M. Bendsøe Optimal shape design as a material distribution problem , 1989 .

[5]  R. Kim,et al.  Tibial Tray Thickness Significantly Increases Medial Tibial Bone Resorption in Cobalt-Chromium Total Knee Arthroplasty Implants. , 2017, The Journal of arthroplasty.

[6]  J. May,et al.  Clinical classification of post-traumatic tibial osteomyelitis. , 1989, The Journal of bone and joint surgery. American volume.

[7]  P. Wooley,et al.  Specific material effects of wear-particle-induced inflammation and osteolysis at the bone–implant interface: A rat model , 2016, Journal of orthopaedic translation.

[8]  Glaucio H. Paulino,et al.  Designing patient-specific 3D printed craniofacial implants using a novel topology optimization method , 2015, Medical & Biological Engineering & Computing.

[9]  P. Chu,et al.  Fully degradable PLA-based composite reinforced with 2D-braided Mg wires for orthopedic implants , 2017 .

[10]  H. Niéto,et al.  Limits of internal fixation in long-bone fracture. , 2017, Orthopaedics & traumatology, surgery & research : OTSR.

[11]  Yanjing Su,et al.  Release of metal ions from nano CoCrMo wear debris generated from tribo-corrosion processes in artificial hip implants. , 2017, Journal of the mechanical behavior of biomedical materials.

[12]  Hao Zhu,et al.  An optimization procedure for spot-welded structures based on SIMP method , 2016 .

[13]  X. Morandi,et al.  Anterior cervical interbody fusion using polyetheretherketone cage filled with synthetic bone graft in acute cervical spine injury. , 2017, Orthopaedics & traumatology, surgery & research : OTSR.

[14]  J. Lackner,et al.  Diamond-like carbon coatings with zirconium-containing interlayers for orthopedic implants. , 2017, Journal of the mechanical behavior of biomedical materials.

[15]  P. Bártolo,et al.  Metallic bone fixation implants: a novel design approach for reducing the stress shielding phenomenon , 2017 .

[16]  M. Zhou,et al.  Checkerboard and minimum member size control in topology optimization , 2001 .

[17]  O. Böstman,et al.  Routine implant removal after fracture surgery: a potentially reducible consumer of hospital resources in trauma units. , 1996, The Journal of trauma.

[18]  L. Murr Open-cellular metal implant design and fabrication for biomechanical compatibility with bone using electron beam melting. , 2017, Journal of the mechanical behavior of biomedical materials.

[19]  M. Wagner,et al.  General principles for the clinical use of the LCP. , 2003, Injury.