FLOWFIELD MEASUREMENTS IN A RIBBED CHANNEL RELEVANT TO INTERNAL TURBINE BLADE COOLING

The internal cooling of turbine blades is an important part of overall blade cooling that is necessary to survive current turbine inlet temperatures. This internal cooling is often performed by means of rib-turbulated passages designed to provide maximum heat transfer coefficients. One determining factor in the cooling effectiveness is the flow pattern created by the ribbed channel. This paper presents a comparison of the effect of two different channel blockage ratios on the fully developed flow pattern in a stationary ribbed channel. For the experimental investigation, a scaled-up ribbed passage was tested using of a closed-loop channel facility. The facility included a passage consisting of a developing region, a fully developed region, a 180° bend, and a second developing region following the bend. Friction factors were determined through the use of pressure taps throughout the channel, and flow fields were measured using a two-component laser Doppler velocimeter. A majority of the testing performed was done under conditions of in-line (i.e. non-staggered) ribs with ratios of rib height to channel hydraulic diameter of 0.10 and 0.17. All LDV measurements were performed at a Reynolds number of 20,000. Results indicate that both blockage ratios create significant recirculation regions immediately before and immediately following the rib. While the smaller rib results indicate a reattachment downstream of the rib, the larger rib results indicate that the flow is separated along the entire streamwise distance between the ribs. The smaller blockage ratio also indicated a small recirculation region directly on top of the rib, whereas the larger blockage ratio showed no such region. Additionally, the increased friction factor created by the larger ribs can be attributed to the larger recirculation regions between ribs.Copyright © 2004 by ASME

[1]  E. Sparrow,et al.  Enhanced heat transfer in a flat rectangular duct with streamwise-periodic disturbances at one principal wall , 1983 .

[2]  Jenn-Jiang Hwang,et al.  Developing Heat Transfer and Friction in a Ribbed Rectangular Duct With Flow Separation at Inlet , 1992 .

[3]  Je-Chin Han,et al.  Developing heat transfer in rectangular channels with rib turbulators , 1988 .

[4]  W. G. Tiederman,et al.  Influence of Wall Strain Rate, Polymer Concentration and Channel Height upon Drag Reduction and Turbulent Structure , 1989 .

[5]  Tony Arts,et al.  Characterization of the Velocity and Heat Transfer Fields in an Internal Cooling Channel With High Blockage Ratio , 2002 .

[6]  T. Arts,et al.  The Effect of Periodic Ribs on the Local Aerodynamic and Heat Transfer Performance of a Straight Cooling Channel , 1996 .

[7]  T. Liou,et al.  LDV Measurements of Periodic Fully Developed Main and Secondary Flows in a Channel With Rib-Disturbed Walls , 1993 .

[8]  Robert J. Moffat,et al.  Describing the Uncertainties in Experimental Results , 1988 .

[9]  Je-Chin Han,et al.  Heat Transfer and Friction in Channels With Two Opposite Rib-Roughened Walls , 1984 .

[10]  Mohammad E. Taslim,et al.  An Experimental Investigation of the Rib Surface-Averaged Heat Transfer Coefficient in a Rib-Roughened Square Passage , 1997 .

[11]  M. Taslim,et al.  Am Experimental Investigation of the Rib Surface-Averaged Heat Transfer Coefficient in a Rib-Roughened Square Passage , 1994 .

[12]  A. Bölcs,et al.  Combined 3D Flow and Heat Transfer Measurements in a 2-Pass Internal Coolant Passage of Gas Turbne Airfoils , 2002 .