Direct interface circuit for capacitive humidity sensors

This paper proposes and analyses a direct interface circuit for capacitive humidity sensors. Such a circuit relies on directly connecting the sensor to a microcontroller without using either a signal conditioner or an analogue-to-digital converter, thus resulting in a simple, compact, low-cost and low-power interface circuit. In spite of its simplicity, the interface circuit performs satisfactorily when measuring commercial capacitive humidity sensors (Philips H1 and Humirel HS1101). The non-linearity error of the interface circuit itself (0.1% full scale span (FSS)) is much smaller than that of the sensor (5.6% FSS for the H1 and 2.1% FSS for the HS1101) and, therefore, the circuit does not limit the accuracy (in terms of linearity) of the measurement, as is to be expected from a well-designed interface circuit. Furthermore, the effective resolution equals 9 bits for a measuring time of 50 ms, which are fully acceptable for humidity measurements.

[1]  Johan H. Huijsing,et al.  Sensors with digital or frequency output , 1988 .

[2]  J. Franca,et al.  A CMOS humidity sensor with on-chip calibration , 2001 .

[3]  Jacob Fraden,et al.  Handbook of modern sensors , 1997 .

[4]  C. W. Watson,et al.  Characterization of a humidity sensor that incorporates a cmos capacitance measuring circuit , 1989 .

[5]  Sabrie Soloman,et al.  Sensors handbook , 1998 .

[6]  R. Pallas-Areny,et al.  Direct interface for capacitive sensors based on the charge transfer method , 2007, 2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007.

[7]  P. O'Leary,et al.  Low-cost, high-precision measurement system for capacitive sensors , 1998 .

[8]  Pedro M. Faia,et al.  Humidity sensing properties of a thick-film titania prepared by a slow spinning process , 2004 .

[9]  Pieter L. Swart,et al.  Determination of equivalent circuit parameters of porous dielectric humidity sensors , 1992 .

[10]  Paul H Dietz,et al.  Wireless liquid level sensing for restaurant applications , 2002, Proceedings of IEEE Sensors.

[11]  Gilles Delapierre,et al.  Polymer-based capacitive humidity sensor: characteristics and experimental results , 1983 .

[12]  Kenzo Watanabe,et al.  A smart thermal environment monitor based on IEEE 1451.2 standard for global networking , 2003, Proceedings of the 20th IEEE Instrumentation Technology Conference (Cat. No.03CH37412).

[13]  J. Kornet,et al.  Long-term tests of capacitive humidity sensors , 1994 .

[14]  Claude Pellet,et al.  Dynamic behavior of a chemical sensor for humidity level measurement in human breath , 2004, IEEE Transactions on Instrumentation and Measurement.

[15]  Gerard C. M. Meijer,et al.  New concepts for smart signal processors and their application to PSD displacement transducers , 1992 .

[16]  Beatrys M. Lacquet,et al.  A new electrical circuit model for porous dielectric humidity sensors , 1993 .

[17]  Noboru Yamazoe,et al.  Humidity sensors: Principles and applications , 1986 .

[18]  K. Watanabe,et al.  A digital hygrometer using a polyimide film relative humidity sensor , 1996 .

[19]  D. D. Denton,et al.  A solid-state relative humidity measurement system , 1990 .

[20]  Z. M. Rittersma,et al.  Recent achievements in miniaturised humidity sensors—a review of transduction techniques , 2002 .

[21]  Manel Gasulla,et al.  Analysis of Power-Supply Interference Effects on Direct Sensor-to-Microcontroller Interfaces , 2005, IEEE Transactions on Instrumentation and Measurement.