Experimental investigation of structure vulnerabilities to firebrand showers

Abstract Attempting to experimentally quantify the vulnerabilities of structures to ignition from firebrand showers has remained elusive. The coupling of two facilities has begun to unravel this difficult problem. The NIST Firebrand Generator (NIST Dragon) is an experimental device that can generate a firebrand shower in a safe and repeatable fashion. Since wind plays a critical role in the spread of WUI fires in the USA and urban fires in Japan, NIST has established collaboration with the Building Research Institute (BRI) in Japan. BRI maintains one of the only full scale wind tunnel facilities in the world designed specifically for fire experimentation; the Fire Research Wind Tunnel Facility (FRWTF). The present investigation is aimed at extensively quantifying firebrand penetration through building vents using full scale tests. A structure was placed inside the FRWTF and firebrand showers were directed at the structure using the NIST Dragon. The structure was fitted with a generic building vent, consisting of only a frame fitted with a metal mesh. Six different mesh sizes openings were used for testing. Behind the mesh, four different materials were placed to ascertain whether the firebrands that were able to penetrate the building mesh assembly could ignite these materials. Reduced scale test methods afford the capability to test new vent technologies and may serve as the basis for new standard testing methodologies. As a result, a new experimental facility developed at NIST is presented and is known as the NIST Dragon's LAIR (Lofting and Ignition Research). The NIST Dragon's LAIR has been developed to simulate a wind driven firebrand attack at reduced scale. The facility consists of a reduced scale Firebrand Generator (Baby Dragon) coupled to a bench scale wind tunnel. Finally, a series of full scale experiments were conducted to visualize the flow of firebrands around obstacles placed downstream of the NIST Dragon. Firebrands were observed to accumulate in front of these obstacles at a stagnation plane, as was observed when the structure was used for firebrand penetration through building vent experiments, due to flow recirculation. The accumulation of firebrands at a stagnation plane presents a severe threat to ignitable materials placed near structures.

[1]  R. A. Anthenien,et al.  On the trajectories of embers initially elevated or lofted by small scale ground fire plumes in high winds , 2006 .

[2]  Haihui Wang Analysis on Downwind Distribution of Firebrands Sourced from a Wildland Fire , 2011 .

[3]  Samuel L. Manzello,et al.  Numerical simulation and experiments of burning douglas fir trees , 2009 .

[4]  Samuel L. Manzello,et al.  On the development and characterization of a firebrand generator , 2008 .

[5]  Yoshihiko Hayashi,et al.  Mass and size distribution of firebrands generated from burning Korean pine (Pinus koraiensis) trees , 2009 .

[6]  Takeyoshi Tanaka,et al.  Transport Of Disk-shaped Firebrands In A Turbulent Boundary Layer , 2005 .

[7]  A. C. Fernandez-Pello,et al.  Numerical study of ground-level distribution of firebrands generated by line fires , 2008 .

[8]  Samuel L. Manzello,et al.  Investigating the Vulnerabilities of Structures to Ignition From a Firebrand Attack , 2008 .

[9]  William Mell,et al.  A case study of a community affected by the witch and guejito fires , 2009 .

[10]  Samuel L. Manzello,et al.  Comparison Testing Protocol for Firebrand Penetration through Building Vents: Summary of BRI/NIST Full Scale and NIST Reduced Scale Results | NIST , 2010 .

[11]  Kevin B. McGrattan,et al.  Fire Dynamics Simulator (Version 5): User's Guide , 2007 .

[12]  I. K. Knight The Design and Construction of a Vertical Wind Tunnel for the Study of Untethered Firebrands in Flight , 2001 .

[13]  A. Carlos Fernandez-Pello,et al.  Modeling transport and combustion of firebrands from burning trees , 2007 .

[14]  F. Usda,et al.  Transport of Firebrands by Line Thermals , 1983 .

[15]  Samuel L. Manzello,et al.  Firebrand generation from burning vegetation , 2007 .

[16]  Samuel L. Manzello,et al.  Quantifying the vulnerabilities of ceramic tile roofing assemblies to ignition during a firebrand attack , 2010 .

[17]  A. Carlos Fernandez-Pello,et al.  On the flight paths of metal particles and embers generated by power lines in high winds--a potential source of wildland fires , 1998 .

[18]  Carlos Sánchez Tarifa,et al.  On the flight pahts and lifetimes of burning particles of wood , 1965 .

[19]  Bernard Porterie,et al.  Experimental validation of a numerical model for the transport of firebrands , 2009 .