Clinicopathologic Correlation of Textural Interface Opacities in Descemet Stripping Automated Endothelial Keratoplasty: A Case Study

Purpose: The aim of this study was to describe the clinicopathologic correlation of textural interface opacities (TIOs) in a Descemet stripping automated endothelial keratoplasty (DSAEK) donor button after its removal. Methods: A 75-year-old woman underwent combined phacoemulsification with intraocular lens placement and DSAEK in her right eye. She had TIOs 1 week postoperatively and continued to have poor visual acuity 8 months postoperatively. The original DSAEK graft was removed, and a repeat DSAEK procedure with a new donor disc was performed. A control corneal button was obtained from a 79-year-old woman who suffered chronic rejection and had a failed DSAEK. Both corneal specimens were sent for light and electron microscopy. Results: Light microscopy of the donor tissue from the patient with TIOs showed stromal irregularities projecting from the cut anterior surface and the expected decrease in the endothelial cell density associated with the procedure and with artifacts. Electron microscopy examination showed irregular collagen fibrils of varying lengths at the stromal surface. Light and electron microscopy examination of the donor tissue from the control patient showed a smooth anterior stromal surface without projecting collagen fibrils. Conclusions: The histopathology of the endothelial disc from the patient with TIOs demonstrated variably irregular lamellae that extended from the anterior donor corneal stromal surface. These extending lamellae were absent on the anterior stromal surface of the control corneal disc, suggesting that they are one possible cause of TIOs and the subsequent suboptimal best-corrected visual acuity and quality of vision experienced by a subset of DSAEK-operated patients.

[1]  S. Hannush,et al.  Textural Interface Opacity After Descemet Stripping Automated Endothelial Keratoplasty: A Report of 30 Cases and Possible Etiology , 2013, Cornea.

[2]  F. Price,et al.  A Cause of Reticular Interface Haze and its Management After Descemet Stripping Endothelial Keratoplasty , 2012, Cornea.

[3]  A. Al-shehri,et al.  Histopathological findings of failed grafts following Descemet's stripping automated endothelial keratoplasty (DSAEK). , 2012, Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society.

[4]  W. Petroll,et al.  Conjunctival Lymphoma in a Child , 2010, Cornea.

[5]  M. Gorovoy,et al.  Epithelial Downgrowth After Descemet Stripping Automated Endothelial Keratoplasty , 2010, Cornea.

[6]  R. Ritch,et al.  Visually significant and nonsignificant complications arising from Descemet stripping automated endothelial keratoplasty. , 2009, American journal of ophthalmology.

[7]  S. Mccormick,et al.  Failed descemet-stripping automated endothelial keratoplasty grafts: a clinicopathologic analysis. , 2009, American journal of ophthalmology.

[8]  G. Kymionis,et al.  Interface wavelike deposits after descemet stripping automated endothelial keratoplasty. , 2009, Archives of ophthalmology.

[9]  K. Goins,et al.  Donor-Related Candida Keratitis After Descemet Stripping Automated Endothelial Keratoplasty , 2009, Cornea.

[10]  A. Jun,et al.  Endothelial keratoplasty: historical perspectives, current techniques, future directions. , 2009, Canadian journal of ophthalmology. Journal canadien d'ophtalmologie.

[11]  R. Fish,et al.  Candida Keratitis After Descemet Stripping and Automated Endothelial Keratoplasty , 2009, Cornea.

[12]  Sander R. Dubovy,et al.  Histopathologic examination of failed grafts in descemet's stripping with automated endothelial keratoplasty. , 2009, Ophthalmology.

[13]  W. Green,et al.  Calcareous Degeneration of Host-Donor Interface After Descemet Membrane Stripping With Automated Endothelial Keratoplasty , 2009, Cornea.

[14]  A. Jun,et al.  A clinicopathologic series of primary graft failure after Descemet's stripping and automated endothelial keratoplasty. , 2009, Ophthalmology.

[15]  W. Culbertson,et al.  Complications of Descemet's stripping with automated endothelial keratoplasty: survey of 118 eyes at One Institute. , 2008, Ophthalmology.

[16]  K. Goins,et al.  Comparison of the Femtosecond Laser (IntraLase) Versus Manual Microkeratome (Moria ALTK) in Dissection of the Donor in Endothelial Keratoplasty: Initial Study in Eye Bank Eyes , 2008, Cornea.

[17]  Sander R. Dubovy,et al.  Diagnosis of residual Descemet's membrane after Descemet's stripping endothelial keratoplasty with anterior segment optical coherence tomography. , 2007, Journal of cataract and refractive surgery.

[18]  F. Price,et al.  Descemet's stripping with endothelial keratoplasty: comparative outcomes with microkeratome-dissected and manually dissected donor tissue. , 2006, Ophthalmology.

[19]  Andrew Carkeet,et al.  Large interface particles from LASIK surgery , 2006, Clinical & experimental optometry.