Design consideration and performance analysis of OCT-based topography

We report a study on design consideration and performance analysis of OCT-based topography by tracking of maximum intensity at each layer’s interface. We demonstrate that, for a given stabilized OCT system, a high precision and accuracy of OCT-based layers and thickness topography in the order of tens nanometer can be achieved by using a technique of maximum amplitude tracking. The submicron precision was obtained by over sampling through the FFT of the acquired spectral fringes but was eventually limited by the system stability. Furthermore, we report characterization of a precision, repeatability, and accuracy of the surfaces, sub-surfaces, and thickness topography using our optimized FD-OCT system. We verified that for a given stability of our OCT system, precision of the detected position of signal’s peak of down to 20 nm was obtained. In addition, we quantified the degradation of the precision caused by sensitivity fall-off over depth of FD-OCT. The measured precision is about 20 nm at about 0.1 mm depth, and degrades to about 80 nm at 1 mm depth, a position of about 10 dB sensitivity fall-off. The measured repeatability of thickness measurements over depth was approximately 0.04 micron. Finally, the accuracy of the system was verified by comparing with a digital micrometer gauging.

[1]  D. C. Streit,et al.  Simultaneous Thickness and Group Index Measurement Using Optical Low- Coherence Reflectometry , 1992 .

[2]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[3]  E. Wolf,et al.  Principles of Optics (7th Ed) , 1999 .

[4]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[5]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[6]  B. Bouma,et al.  Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. , 2003, Optics letters.

[7]  Susana Marcos,et al.  Three-dimensional reconstruction of the crystalline lens gradient index distribution from OCT imaging. , 2010, Optics express.

[8]  G. Coscas Comprar Optical Coherence Tomography in Age-Related Macular Degeneration | Coscas, Gabriel | 9783642101816 | Springer , 2010 .

[9]  A. Fercher,et al.  Measurement of intraocular distances by backscattering spectral interferometry , 1995 .

[10]  J. Fujimoto,et al.  Optical coherence tomography: technology and applications , 2002, IEEE/LEOS International Conference on Optical MEMs.

[11]  Jannick P. Rolland,et al.  Optical Coherence Tomography Enabling Non Destructive Metrology of Layered Polymeric GRIN Material , 2013, Scientific Reports.

[12]  Eric Clarkson,et al.  Task-based optimization and performance assessment in optical coherence imaging. , 2005, Journal of the Optical Society of America. A, Optics, image science, and vision.