FIT2D: a multi-purpose data reduction, analysis and visualization program

FIT2D is one of the principal area detector data reduction, analysis and visualization programs used at the European Synchrotron Radiation Facility and is also used by more than 400 research groups worldwide, including many other synchrotron radiation facilities. It has been developed for X-ray science, but is applicable to other structural techniques and is used in analysing electron diffraction data and microscopy, and neutron diffraction and scattering data. FIT2D works for both interactive and `batch'-style data processing. Calibration and correction of detector distortions, integration of two-dimensional data to a variety of one-dimensional scans, and one- and two-dimensional model fitting are the main uses. Many other general-purpose image processing and image visualization operations are available. Commands are available through a `graphical user interface' and operations common to certain types of analysis are grouped within `interfaces'. Executable versions for most workstation and personal computer systems, and web page documentation, are available at http://www.esrf.eu/computing/scientific/FIT2D.

[1]  C. Riekel,et al.  Crystalline Ultrastructure of Starch Granules Revealed by Synchrotron Radiation Microdiffraction Mapping , 1997 .

[2]  A. P. Hammersley,et al.  Calibration and correction of spatial distortions in 2D detector systems , 1994 .

[3]  A. Mahendrasingam,et al.  Collecting and Processing Neutron Fibre Diffraction Data from a Single-Crystal Diffractometer , 1996 .

[4]  J. Janin,et al.  Macromolecular crystallography with synchrotron radiation: photographic data collection and polarization correction , 1982 .

[5]  Paul Dierckx,et al.  Curve and surface fitting with splines , 1994, Monographs on numerical analysis.

[6]  David J. Thomas Calibrating an area-detector diffractometer: integral response , 1990, Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences.

[7]  S. McSweeney,et al.  A Novel Technique for Accurate Intensity Calibration of Area X-ray Detectors at Almost Arbitrary Energy. , 1996, Journal of Synchrotron Radiation.

[8]  Alessandro Curioni,et al.  On the Crystal Structure of Azafullerene (C59N)2 , 1996 .

[9]  P. Toulemonde,et al.  In situ study of the synthesis of Hg2Ba2YCu2O8-δ at high pressure and high temperature by x-ray synchrotron diffraction , 2000 .

[10]  J. Squire,et al.  Myosin head configuration in relaxed fish muscle: resting state myosin heads must swing axially by up to 150 A or turn upside down to reach rigor. , 1997, Journal of molecular biology.

[11]  Chris Hall,et al.  2D detectors for synchrotron X-ray sources, some comparative tests , 1991 .

[12]  J. Crain,et al.  An imaging plate system for high‐pressure powder diffraction: The data processing side , 1992 .

[13]  A. P. Hammersley,et al.  Two-dimensional detector software: From real detector to idealised image or two-theta scan , 1996 .

[14]  David Gur,et al.  Signal fading, erasure, and rescan in storage phosphor imaging , 1992, Medical Imaging.

[15]  R. Templer Measurements on some characteristics of BaFBr : Eu2+, relevant to its use as a storage phosphor for X-ray diffraction imaging , 1991 .

[16]  Youli Li,et al.  Correcting spatial distortions and nonuniform response in area detectors , 1992 .

[17]  M. Kunz,et al.  An improved X-ray detector for use at synchrotrons , 1998 .

[18]  H. Graafsma,et al.  Calibration and correction of distortions in two‐dimensional detector systemsa) , 1995 .

[19]  David J. Thomas Calibrating an area-detector diffractometer: imaging geometry , 1989, Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences.

[20]  P. R. Bevington,et al.  Data Reduction and Error Analysis for the Physical Sciences, 2nd ed. , 1993 .

[21]  J. S. Rollett,et al.  Statistical descriptors in crystallography: Report of the IUCr Subcommittee on Statistical Descriptors , 1989 .

[22]  A. Hammersley,et al.  Molecular packing of type I collagen in tendon. , 1998, Journal of molecular biology.

[23]  C. Riekel,et al.  MFIT: Multiple spectra fitting program , 1989 .

[24]  N. Yasuoka,et al.  Evaluation of x-ray diffraction data from protein crystals by use of an imaging plate. , 1991, Acta crystallographica. Section B, Structural science.

[25]  C. Boulin,et al.  Data appraisal, evaluation and display for synchrotron radiation experiments: Hardware and software , 1986 .

[26]  Philip E. Gill,et al.  Practical optimization , 1981 .

[27]  Christina Kluge,et al.  Data Reduction And Error Analysis For The Physical Sciences , 2016 .