Exact Feedback Linearization (EFL) and De-Couple Control of Doubly Fed Induction Generator Based Wind Turbine

To trace maximum power points (MPP) d-axis and q-axis stator currents are required to be controlled individually, and decoupled for grid voltage support and reactive power injection during the grid faults. A decoupling method for Doubly Fed Induction Generator (DFIG) tied with grid is presented by Exact Feedback Linearization (EFL) based on differential geometry. State feedback linearization conditions are illustrated to check whether the nonlinear system is linearizable or not. State feedback control law which decouples active and reactive powers. The control law is simplified and designed to ensure its realization in practical engineering. The d-q modeling of DFIG is carried out using MATLAB/Simulink in term of synchronous reference frame. The simulations result shows that the proposed control scheme can exactly linearized the DFIG system.

[1]  Jafar Soltani,et al.  Nonlinear torque and stator flux controller for induction motor drive based on adaptive input–output feedback linearization and sliding mode control , 2008 .

[2]  Chang-song Wang,et al.  Exact Feedback Linearization and Decoupling Control of Doubly Fed Induction Generator , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[3]  Shengwei Mei,et al.  Nonlinear Control Systems and Power System Dynamics , 2001, The Springer International Series on Asian Studies in Computer and Information Science.

[4]  Siavash Beheshtaein,et al.  FAΘPSO based fuzzy controller to enhance LVRT capability of DFIG with dynamic references , 2014, 2014 IEEE 23rd International Symposium on Industrial Electronics (ISIE).

[5]  Samee U. Khan,et al.  Exact feedback linearization‐based permanent magnet synchronous generator control , 2016 .

[6]  Bin Wu,et al.  High-power wind energy conversion systems: State-of-the-art and emerging technologies , 2015, Proceedings of the IEEE.

[7]  Xu Cai,et al.  Decoupled control of active and reactive power for a grid-connected doubly-fed induction generator , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[8]  K B Mohanty Input-Output Linearizing and Decoupling Control of an Induction Motor Drive , 2007 .

[9]  Xu Cai,et al.  Simplified input-output linearizing and decoupling control of wind turbine driven doubly-fed induction generators , 2009, 2009 IEEE 6th International Power Electronics and Motion Control Conference.