False air-bone gaps at 4 kHz in listeners with normal hearing and sensorineural hearing loss

Abstract Objective: This report presents data from four studies to examine standard bone-conduction reference equivalent threshold force levels (RETFL), especially at 4 kHz where anomalous air-bone gaps are common. Design: Data were mined from studies that obtained air- and bone-conduction thresholds from normal-hearing and sensorineural hearing loss (SNHL) participants, using commercial audiometers and standard audiometric transducers. Study sample: There were 249 normal-hearing and 188 SNHL participants. Results: (1) Normal-hearing participants had small air-bone gaps at 0.5, 1.0, and 2.0 kHz (‐1.7 to 0.3 dB) and larger air-bone gaps at 4 kHz (10.6 dB). (2) SNHL participants had small air-bone gaps at 0.5, 1.0, and 2.0 kHz (‐0.7 to 1.7 dB) and a larger air-bone gap at 4 kHz (14.1 dB). (3) The 4-kHz air-bone gap grew with air-conduction threshold from 10.1 dB when the air-conduction threshold was 5–10 dB HL to 21.1 dB when the air-conduction threshold was greater than 60 dB. (4) With the 4-kHz RETFL corrected by the average SNHL air-bone gap, the relationship between RETFL and frequency is linear with a slope of − 12 dB per octave. Conclusions: The 4-kHz air-bone gaps for listeners with SNHL could be avoided by adjusting the 4-kHz RETFL by − 14.1 dB.

[1]  L. Wilber,et al.  Real ear versus artificial mastoid methods of calibration of bone-conduction vibrators. , 1967, Journal of speech and hearing research.

[2]  Brian C J Moore,et al.  AMTAS®: Automated method for testing auditory sensitivity: Validation studies , 2010, International journal of audiology.

[3]  A. Glorig,et al.  Changes in Air and Bone Conduction Thresholds as a Function of Age , 1962, The Journal of Laryngology & Otology.

[4]  W. Olsen,et al.  Bone conduction calibration: current status. , 1979, The Journal of speech and hearing disorders.

[5]  Donald D. Dirks,et al.  Bone-Vibrator Measurements: Physical Characteristics and Behavioral Thresholds , 1975 .

[6]  Robert H Margolis,et al.  Qualind: A method for assessing the accuracy of automated tests. , 2007, Journal of the American Academy of Audiology.

[7]  D. Swanepoel,et al.  Self-reported hearing loss in baby boomers from the Busselton Healthy Ageing Study: audiometric correspondence and predictive value. , 2013, Journal of the American Academy of Audiology.

[8]  Brian C J Moore,et al.  AMTAS®: Automated method for testing auditory sensitivity: III. Sensorineural hearing loss and air-bone gaps , 2011, International journal of audiology.

[9]  M S Shipton,et al.  A standard determination of paired air- and bone-conduction thresholds under different masking noise conditions. , 1982, Audiology : official organ of the International Society of Audiology.

[10]  Robert H Margolis,et al.  Acoustic method for calibration of audiometric bone vibrators. , 2012, The Journal of the Acoustical Society of America.

[11]  T. Frank,et al.  Acoustic Radiation from Bone Vibrators , 1981, Ear and hearing.

[12]  M S Shipton,et al.  Air-radiated sound from bone vibration transducers and its implications for bone conduction audiometry. , 1980, British journal of audiology.

[13]  C. Crandell,et al.  Acoustic radiation produced by B-71, B-72, and KH 70 bone vibrators. , 1986, Ear and hearing.

[14]  Robert H Margolis,et al.  AMTAS®: Automated method for testing auditory sensitivity: II. Air conduction audiograms in children and adults , 2011, International journal of audiology.

[15]  G. Lightfoot,et al.  Bone conduction errors at high frequencies: implications for clinical and medico-legal practice , 1993, The Journal of Laryngology & Otology.

[16]  De Wet Swanepoel,et al.  Clinical validation of the AMTAS automated audiometer , 2013, International journal of audiology.

[17]  A R Thornton,et al.  A brief communication on bone conduction artefacts. , 1980, British journal of audiology.

[18]  L A Wilber Comparability of two commercially available artificial mastoids. , 1972, The Journal of the Acoustical Society of America.

[19]  L. S. Whittle A determination of the normal threshold of hearing by bone conduction , 1965 .

[20]  Chris A. Sanford,et al.  Age effects in the human middle ear: wideband acoustical measures. , 2004, The Journal of the Acoustical Society of America.

[21]  G. Lightfoot Air-borne radiation from bone conduction transducers. , 1979, British journal of audiology.

[22]  Stefan Stenfelt,et al.  A model of the occlusion effect with bone-conducted stimulation , 2007, International journal of audiology.

[23]  I H Jones,et al.  FUNCTIONAL TESTS OF HEARING. , 1924, California and western medicine.