Superconducting noise bolometer with microwave bias and readout for array applications

We present a superconducting noise bolometer for terahertz radiation, which is suitable for large-format arrays. It is based on an antenna-coupled superconducting micro-bridge embedded in a high-quality factor superconducting resonator for a microwave bias and readout with frequency-division multiplexing in the GHz range. The micro-bridge is kept below its critical temperature and biased with a microwave current of slightly lower amplitude than the critical current of the micro-bridge. The response of the detector is the rate of superconducting fluctuations, which depends exponentially on the concentration of quasiparticles in the micro-bridge. Excess quasiparticles are generated by an incident THz signal. Since the quasiparticle lifetime increases exponentially at lower operation temperature, the noise equivalent power rapidly decreases. This approach allows for large arrays of noise bolometers operating above 1 K with sensitivity, limited by 300-K background noise. Moreover, the response of the bolometer always dominates the noise of the readout due to relatively large amplitude of the bias current. We performed a feasibility study on a proof-of-concept device with a ${1.0\times 0.5 \rm \mu m^{2}}$ micro-bridge from a 9-nm thin Nb film on a sapphire substrate. Having a critical temperature of 5.8 K, it operates at 4.2 K and is biased at the frequency 5.6 GHz. For the quasioptical input at 0.65 THz, we measured the noise equivalent power ${\approx 3\times 10^{-12}\rm W/\sqrt Hz}$ , which is close to expectations for this particular device in the noise-response regime.

[1]  Arttu Luukanen,et al.  Optical and Electrical Characterization of a Large Kinetic Inductance Bolometer Focal Plane Array , 2017, IEEE Transactions on Terahertz Science and Technology.

[2]  Michael Siegel,et al.  Progress in Development of the Superconducting Bolometer With Microwave Bias and Readout , 2017, IEEE Transactions on Applied Superconductivity.

[3]  M. Siegel,et al.  Operation of Superconducting Nanowire Single-Photon Detectors Embedded in Lumped-Element Resonant Circuits , 2016, IEEE Transactions on Applied Superconductivity.

[4]  M. Siegel,et al.  Novel Detection Scheme for Cryogenic Bolometers With High Sensitivity and Scalability , 2015, IEEE Transactions on Applied Superconductivity.

[5]  M. Siegel,et al.  Wide-Range Bolometer With RF Readout TES , 2014, IEEE Transactions on Applied Superconductivity.

[6]  Andrew D. Burnett,et al.  Terahertz imaging using quantum cascade lasers—a review of systems and applications , 2014 .

[7]  Erik Heinz,et al.  Progress in passive submillimeter-wave video imaging , 2014, Defense + Security Symposium.

[8]  Thierry Robin,et al.  Terahertz applications: trends and challenges , 2014, Photonics West - Optoelectronic Materials and Devices.

[9]  B. Bousquet,et al.  Review of Terahertz Tomography Techniques , 2014 .

[10]  Arttu Luukanen,et al.  Submillimeter-wave kinetic inductance bolometers on free-standing nanomembranes , 2014 .

[11]  Mikko Leivo,et al.  Passive three-colour submillimetre-wave video camera , 2013, Defense, Security, and Sensing.

[12]  N. Llombart,et al.  Operation of a titanium nitride superconducting microresonator detector in the nonlinear regime , 2013, 1305.4281.

[13]  M. Siegel,et al.  TES Bolometers With High-Frequency Readout Circuit , 2013, IEEE Transactions on Terahertz Science and Technology.

[14]  Dan Werthimer,et al.  A readout for large arrays of microwave kinetic inductance detectors. , 2012, The Review of scientific instruments.

[15]  S. Anlage,et al.  Microscopic examination of hot spots giving rise to nonlinearity in superconducting resonators , 2011, 1108.3378.

[16]  P. Goldbart,et al.  Cratered Lorentzian response of driven microwave superconducting nanowire-bridged resonators: Oscillatory and magnetic-field induced stochastic states , 2011, 1101.0817.

[17]  S. Withington,et al.  Readout-power heating and hysteretic switching between thermal quasiparticle states in kinetic inductance detectors , 2010 .

[18]  V. G. Kogan,et al.  Vortex-induced dissipation in narrow current-biased thin-film superconducting strips , 2010, 1102.5130.

[19]  M. Siegel,et al.  Current-assisted thermally activated flux liberation in ultrathin nanopatterned NbN superconducting meander structures , 2009, 0911.1880.

[20]  H. Seppa,et al.  NbN Vacuum Bridge Bolometer Arrays With Room Temperature Readout Approaching Photon Noise Limited THz Imaging Applications , 2007, IEEE Transactions on Applied Superconductivity.

[21]  R. Barends,et al.  Current-induced vortex unbinding in bolometer mixers , 2005 .

[22]  M. Siegel,et al.  Superconducting noise bolometer for terahertz radiation , 2005 .

[23]  A. Semenov Superconducting submillimeter direct detector using high-frequency current noise , 2004 .

[24]  H. Leduc,et al.  A broadband superconducting detector suitable for use in large arrays , 2003, Nature.

[25]  M. Gaidis,et al.  Optical properties of Zitex in the infrared to submillimeter. , 2003, Applied optics.

[26]  Arttu Luukanen,et al.  A superconducting antenna-coupled hot-spot microbolometer , 2003 .

[27]  Boris S. Karasik,et al.  Ultrasensitive hot-electron kinetic-inductance detectors operating well below the superconducting transition , 2002 .

[28]  Alexander Korneev,et al.  Quantum detection by current carrying superconducting film , 2001 .

[29]  G. Gol'tsman,et al.  Influence of phonon trapping on the performance of NbN kinetic inductance detectors , 1997, IEEE Transactions on Applied Superconductivity.

[30]  Cheng-Chung Chi,et al.  Quasiparticle and phonon lifetimes in superconductors , 1976 .