Indoor air quality investigation from screen printing industry

The paper investigates the quality of air in working premises of screen printing in Novi Sad, Serbia. The concentrations of Volatile Organic Compounds, formaldehyde, acetone and ozone were measured in a five screen printing facilities. Measurements were carried out during 4h, every 40min, using the air sampler PRO-EKOS AT 401X and mobile gas chromatograph. The sampling position was determined according to the technical characteristics of screen printing desk. Air was sampled from one sampling point as the most suitable in terms of production volume. Determined concentrations of certain gases indicate not only their presence, but also the fact that their level exceeds the prescribed value of the OSHA and NIOSH standards. The concentrations of acetone, isopropanol and methyl ethyl ketone increased from 0.120 to 0.214ppm within 80min of printing process in most investigated facilities. The ozone concentrations varied from 0.650 to 3.997ppm and they differ between facilities almost 1.5 to 6 times depending on intensity of the ventilation, diffusion processes, or interaction with other Volatile Organic Compounds of indoor air. The obtained results confirmed the existence of mutual dependence between pollutants. The regression models determined the quantitative dependence of the studied phenomenon.

[1]  Kenneth A. Zarker,et al.  Pollution prevention through performance-based initiatives and regulation in the United States , 2008 .

[3]  D. Saraga,et al.  Studying the indoor air quality in three non-residential environments of different use: A museum, a , 2011 .

[4]  Jelena S. Kiurski,et al.  Detection and Quantification of Ozone in Screen Printing Facilities , 2011 .

[5]  P. Lioy,et al.  Health Effects of a Mixture of Indoor Air Volatile Organics, Their Ozone Oxidation Products, and Stress , 2005, Environmental health perspectives.

[6]  R. Gunst Regression analysis and its application , 1980 .

[7]  Emmanuel D. Adamides,et al.  Industrial ecosystems as technological niches , 2009 .

[8]  Matti Melanen,et al.  Waste minimisation in small and medium-sized enterprises—do environmental management systems help? , 2001 .

[9]  M. Tadé,et al.  Volatile organic compounds in indoor environment and photocatalytic oxidation: state of the art. , 2007, Environment international.

[10]  Baba Md Deros,et al.  Indoor air quality issues for non-industrial work place. , 2010 .

[11]  John D. Spengler,et al.  Criteria air pollutants and toxic air pollutants. , 2000 .

[12]  P. Lioy,et al.  Current State of the Science: Health Effects and Indoor Environmental Quality , 2007, Environmental health perspectives.

[13]  Aysen Muezzinoglu,et al.  Air pollutant emission potentials of cotton textile manufacturing industry , 1998 .

[14]  T L Dawson,et al.  Ink‐jet printing of textiles under the microscope , 2000 .

[15]  Chun-Ho Liu,et al.  Occupational Exposure to Volatile Organic Compounds and Mitigation by Push‐Pull Local Exhaust Ventilation in Printing Plants , 2005, Journal of occupational health.

[16]  A. P. Altshuller,et al.  Determination of Formaldehyde in Gas Mixtures by the Chromotropic Acid Method , 1961 .

[17]  J. Galloo,et al.  An automated monitoring system for VOC ozone precursors in ambient air: development, implementation and data analysis , 2004, Analytical and bioanalytical chemistry.

[19]  R M Harrison,et al.  Concentrations and sources of VOCs in urban domestic and public microenvironments. , 2001, Environmental science & technology.

[20]  H. K. Fai,et al.  Characterization of VOCs, ozone, and PM10 emissions from office equipment in an environmental chamber , 2001 .

[21]  Luoping Zhang,et al.  Formaldehyde in China: production, consumption, exposure levels, and health effects. , 2009, Environment international.

[22]  J. Oosthuizen,et al.  Environmental Health - Emerging Issues and Practice , 2012 .

[23]  Joonas Auvinen,et al.  The influence of photocatalytic interior paints on indoor air quality , 2008 .