Low-Cost Blood Pressure Monitor Device for Developing Countries

Taking the Blood Pressure (BP) with a traditional sphygmomanometer requires a trained user. In developed countries, patients who need to monitor their BP at home usually acquire an electronic BP device with an automatic inflate/deflate cycle that determines the BP through the oscillometric method. For patients in resource constrained regions automated BP measurement devices are scarce because supply channels are limited and relative costs are high. Consequently, routine screening for and monitoring of hypertension is not common place. In this project we aim to offer an alternative strategy to measure BP and Heart Rate (HR) in developing countries. Given that mobile phones are becoming increasingly available and affordable in these regions, we designed a system that comprises low-cost peripherals with minimal electronics, offloading the main processing to the phone. A simple pressure sensor passes information to the mobile phone and the oscillometric method is used to determine BP and HR. Data are then transmitted to a central medical record to reduce errors in time stamping and information loss.

[1]  K. Reynolds,et al.  Global burden of hypertension: analysis of worldwide data , 2005, The Lancet.

[2]  Hui Li,et al.  Prevalence, awareness, treatment, and control of hypertension in rural China: results from Shandong Province , 2010, Journal of hypertension.

[3]  L. A. Geddes,et al.  Handbook of Blood Pressure Measurement , 1991 .

[4]  G. Drzewiecki,et al.  Theory of the oscillometric maximum and the systolic and diastolic detection ratios , 2006, Annals of Biomedical Engineering.

[5]  Stephen Colagiuri,et al.  Grand challenges in chronic non-communicable diseases , 2007, Nature.

[6]  António Prista,et al.  Hypertension Prevalence, Awareness, Treatment, and Control in Mozambique: Urban/Rural Gap During Epidemiological Transition , 2009, Hypertension.

[7]  D. Westenskow,et al.  Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure , 1997, Medical and Biological Engineering and Computing.

[8]  Chin-Teng Lin,et al.  Reduction of interference in oscillometric arterial blood pressure measurement using fuzzy logic , 2003, IEEE Trans. Biomed. Eng..

[9]  G. Clifford,et al.  An analysis of the errors in recorded heart rate and blood pressure in the ICU using a complex set of signal quality metrics , 2007, 2007 Computers in Cardiology.

[10]  R. Malkin Design of health care technologies for the developing world. , 2007, Annual review of biomedical engineering.

[11]  C. Goonasekera,et al.  Random zero sphygmomanometer versus automatic oscillometric blood pressure monitor; is either the instrument of choice? , 1995, Journal of human hypertension.

[12]  Waqas Ahmed,et al.  Comparison of Oscillometric and Intraarterial Systolic and Diastolic Blood Pressures in Lean, Overweight, and Obese Patients , 2006, Angiology.

[13]  N. Banatvala,et al.  Chronic diseases in developing countries , 2007, The Lancet.

[14]  Ajay K. Singh,et al.  Hypertension in the developing world: challenges and opportunities. , 2010, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[15]  A. Damasceno,et al.  Hypertension Prevalence, Awareness, Treatment, and Control in Mozambique: Urban/Rural Gap During Epidemiological Transition , 2009, Hypertension.

[16]  A. Reisner,et al.  Clinician blood pressure documentation of stable intensive care patients: An intelligent archiving agent has a higher association with future hypotension , 2011, Critical care medicine.

[17]  I. Niubo,et al.  An experience in implementing the oscillometric algorithm for the noninvasive determination of human blood pressure , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[18]  Chin-Teng Lin,et al.  Model-based synthetic fuzzy logic controller for indirect blood pressure measurement , 2002, IEEE Trans. Syst. Man Cybern. Part B.

[19]  A. Shennan,et al.  Accuracy of oscillometric blood pressure monitoring in pregnancy and pre‐eclampsia , 1997, British journal of obstetrics and gynaecology.

[20]  Alan D. Lopez,et al.  Mortality by cause for eight regions of the world: Global Burden of Disease Study , 1997, The Lancet.

[21]  A W Halligan,et al.  Comparison of auscultatory and oscillometric automated blood pressure monitors in the setting of preeclampsia. , 1999, American journal of obstetrics and gynecology.