Acceptance Criteria for Unbonded Post-Tensioned Concrete Exposed to Travelling and Traditional Design Fires

Modern architecture is striving for large open spaces, which has resulted in the development of design methodologies such as the Improved Travelling Fires Methodology (iTFM). This methodology is only applicable in large open spaces where flashover may not occur. This paper studies the effect of various design fires, including traditional uniform fires and for the first time iTFM on flat-plate unbonded post-tensioned (UPT) concrete, a structural system which allows long flooring spans (> 8 m). The predictions of a structural model of high temperature unbonded prestressing tendon relaxation that is available in the literature are compared for the first time with previously published fire experiments thus validating the model. A novel case study based on a real building was then analysed using the model to propose an acceptance criterion based on the longest tendon length where rupture and extreme stress relaxation is prevented. Two types of steel, fabricated according to BS 5896 and AS/NZ4672, were analysed for various unbonded lengths (between 8.15 m and 65.2 m). Emphasis is on the unique deformation mechanisms present when prestressing steel is heated locally. The relaxation model has been validated for negligible slab deflection, allowing for discussion on the difference between the impact of travelling and uniform fires on the design of UPT concrete. The tendon rupture and relaxation analysis have novelty in showing that slow moving fires are more onerous structurally than fast moving or uniform fires and therefore are important to consider when defining critical design thermal boundaries in a design context. Results also demonstrate that tendons in similar designs require consideration to be limited in unbonded length. The development of new acceptance criteria herein is the first step in producing a generalized criteria for better informed structural fire design of UPT concrete exposed to fire.

[1]  Guillermo Rein,et al.  Improved Formulation of Travelling Fires and Application to Concrete and Steel Structures , 2015 .

[2]  Guillermo Rein,et al.  Travelling fires for structural design-Part II: Design methodology , 2012 .

[3]  Dougal Drysdale,et al.  Heat transfer analysis of the composite slab in the Cardington frame fire tests , 2001 .

[4]  Luke Bisby,et al.  Structural Fire Performance of Contemporary Post-tensioned Concrete Construction , 2016, SpringerBriefs in Fire.

[5]  Guillermo Rein,et al.  The influence of travelling fires on a concrete frame , 2011 .

[6]  Ehab Ellobody,et al.  Structural performance of a post-tensioned concrete floor during horizontally travelling fires , 2011 .

[7]  Luke Bisby,et al.  Creep of prestressing steels in fire , 2016 .

[8]  David Rush,et al.  The thermal and structural performance of a concrete column exposed to a travelling fire – tisova fire test , 2016 .

[9]  Ehab Ellobody,et al.  Fire tests on unbonded post-tensioned one-way concrete slabs , 2009 .

[10]  Monther B. Dwaikat,et al.  A numerical model for predicting the fire resistance of reinforced concrete beams , 2008 .

[11]  Jean-Marc Franssen,et al.  Experimental research on the determination of the main parameters affecting the behaviour of reinforced concrete columns under fire conditions. , 1997 .

[12]  František Wald,et al.  Temperature heterogeneity during travelling fire on experimental building , 2013, Adv. Eng. Softw..

[13]  G. Khoury Effect of fire on concrete and concrete structures , 2000 .

[14]  Yong Wang,et al.  The effect of load-induced thermal strain on flat slab behaviour at elevated temperatures , 2018 .

[15]  Asif Usmani,et al.  A critical review of “travelling fire” scenarios for performance-based structural engineering , 2017 .

[16]  Asif Usmani,et al.  Behaviour of a small composite steel frame structure in a “long-cool” and a “short-hot” fire , 2004 .

[17]  Panagiotis Kotsovinos,et al.  Flame extension and the near field under the ceiling for travelling fires inside large compartments , 2019 .

[18]  Guillermo Rein,et al.  Travelling fires for structural design-Part I: Literature review , 2012 .

[19]  Fahim Sadek,et al.  Structural Response of World Trade Center Buildings 1, 2 and 7 to Impact and Fire Damage , 2013 .

[20]  Thomas Gernay,et al.  Awarding Ceremony McKinsey & Company Scientific Prize: A multiaxial constitutive model for concrete in the fire situation , 2013 .

[21]  Linus C. S. Lim Stability of Precast Concrete Tilt Panels in Fire , 2000 .

[22]  Luke Bisby,et al.  Unbonded Post Tensioned Concrete Slabs in Fire – Part II – Modelling Tendon Response and the Consequences of Localized Heating , 2011 .

[23]  Angus Law The Assessment and Response of Concrete Structures Subject to Fire , 2010 .

[24]  Robby Caspeele,et al.  Fire resistance of concrete slabs acting in compressive membrane action , 2017 .

[25]  Fahim Sadek,et al.  International R and D Roadmap for Fire Resistance of Structures Summary of NIST/CIB Workshop , 2015 .

[26]  Luke Bisby,et al.  Transient high-temperature stress relaxation of prestressing tendons in unbonded construction , 2009 .

[27]  Panagiotis Kotsovinos,et al.  Analysis of the structural response of tall buildings under multifloor and travelling fires , 2013 .

[28]  Panagiotis Kotsovinos,et al.  Structural analysis of multi-storey steel frames exposed to travelling fires and traditional design fires , 2017 .