Validation of Dynamic optical coherence tomography for non-invasive, in vivo microcirculation imaging of the skin.

OBJECTIVES Dynamic optical coherence tomography (D-OCT) is an angiographic variation of OCT that non-invasively provides images of the in vivo microvasculature of the skin by combining conventional OCT images with flow data. The objective of this study was to investigate and report on the D-OCT technique for imaging of the vascular networks in skin as well as to validate the method by comparing the results against already accepted blood flow measuring tools. METHODS 35 healthy subjects were recruited for the multicentre study, consisting of three experiments set up to examine the vascular blood perfusion during different induced physiologic changes in the blood flow. In order to validate the D-OCT images against existing techniques for blood flow measuring we performed consecutive D-OCT, chromametry and laser speckle contrast imager (LSCI) measurements on identical skin sites in all of the experiments. Blinded observer evaluations were performed in order to evaluate the vascular morphology in the D-OCT images. RESULTS The results showed a statistically significant positive correlation between the D-OCT measurements and the LCSI flux measurements (rs=0.494; 95% CI [0.357, 0.615]; p<0.001), and also the redness a* measurements were positively correlated with the D-OCT measurements (r=0.48; 95% CI [0.406, 0.55]). D-OCT was able to reliably image and identify morphologic changes in the vascular network consistent with the induced physiological changes of blood flow. CONCLUSION This study has initiated validation of the use of D-OCT for imaging of skin blood flow. Our results showed that D-OCT was able to reliably image and identify changes in the skin vasculature consistent with the induced physiological blood flow changes. These basic findings support the use of D-OCT imaging for in vivo microcirculation imaging of the skin.

[1]  Can Ince,et al.  Validation of near-infrared laser speckle imaging for assessing microvascular (re)perfusion. , 2010, Microvascular research.

[2]  G. Pellacani,et al.  In vivo, micro‐morphological vascular changes induced by topical brimonidine studied by Dynamic optical coherence tomography , 2016, Journal of the European Academy of Dermatology and Venereology : JEADV.

[3]  C. Berking,et al.  The sensitivity and specificity of optical coherence tomography for the assisted diagnosis of nonpigmented basal cell carcinoma: an observational study , 2015, The British journal of dermatology.

[4]  J. R. Landis,et al.  The measurement of observer agreement for categorical data. , 1977, Biometrics.

[5]  T. Jørgensen,et al.  Optical coherence tomography in dermatology , 2006 .

[6]  C. Grana,et al.  Dynamic Optical Coherence Tomography in Dermatology , 2016, Dermatology.

[7]  M. Khandwala,et al.  In vivo optical coherence tomography (OCT) in periocular basal cell carcinoma: correlations between in vivo OCT images and postoperative histology , 2013, British Journal of Ophthalmology.

[8]  M. Cutolo,et al.  Correlations between skin blood perfusion values and nailfold capillaroscopy scores in systemic sclerosis patients. , 2016, Microvascular research.

[9]  R. Hofmann-Wellenhof,et al.  High‐definition optical coherence tomography algorithm for discrimination of basal cell carcinoma from clinical BCC imitators and differentiation between common subtypes , 2015, Journal of the European Academy of Dermatology and Venereology : JEADV.

[10]  Matthieu Roustit,et al.  Assessment of endothelial and neurovascular function in human skin microcirculation. , 2013, Trends in pharmacological sciences.

[11]  Wolfgang Drexler,et al.  In situ structural and microangiographic assessment of human skin lesions with high-speed OCT , 2012, Biomedical optics express.

[12]  H. Tran,et al.  Blood pressure and blood flow variation during postural change from sitting to standing: model development and validation. , 2005, Journal of applied physiology.

[13]  P. Clarys,et al.  Skin color measurements: comparison between three instruments: the Chromameter®, the DermaSpectrometer® and the Mexameter® , 2000, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[14]  J. Holmes,et al.  In vivo micro‐angiography by means of speckle‐variance optical coherence tomography (SV‐OCT) is able to detect microscopic vascular changes in naevus to melanoma transition , 2016, Journal of the European Academy of Dermatology and Venereology : JEADV.

[15]  C. Berking,et al.  Morphology of basal cell carcinoma in high definition optical coherence tomography: en‐face and slice imaging mode, and comparison with histology , 2013, Journal of the European Academy of Dermatology and Venereology : JEADV.

[16]  Peijun Gong,et al.  Optical coherence tomography for longitudinal monitoring of vasculature in scars treated with laser fractionation , 2016, Journal of biophotonics.

[17]  Ruikang K. Wang,et al.  OCT-based label-free in vivo lymphangiography within human skin and areola , 2016, Scientific Reports.

[18]  Ruikang K. Wang,et al.  Improved microcirculation imaging of human skin in vivo using optical microangiography with a correlation mapping mask , 2014, Journal of biomedical optics.

[19]  Ruikang K. Wang,et al.  Potential use of OCT‐based microangiography in clinical dermatology , 2016, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[20]  Ruikang K. Wang,et al.  Optical coherence tomography microangiography for monitoring the response of vascular perfusion to external pressure on human skin tissue , 2014, Journal of biomedical optics.

[21]  J. Nilsson,et al.  Non-invasive imaging of microcirculation: a technology review , 2014, Medical devices.

[22]  M. Roustit,et al.  Non‐invasive Assessment of Skin Microvascular Function in Humans: An Insight Into Methods , 2012, Microcirculation.

[23]  G. Jemec,et al.  Optical coherence tomography imaging of telangiectasias during intense pulsed light treatment: a potential tool for rapid outcome assessment , 2013, Archives of Dermatological Research.

[24]  Ruikang K. Wang,et al.  Methods and algorithms for optical coherence tomography-based angiography: a review and comparison , 2015, Journal of biomedical optics.

[25]  Erik L Ritman,et al.  The human cutaneous circulation as a model of generalized microvascular function. , 2008, Journal of applied physiology.

[26]  Adam Trendowicz,et al.  Model Development and Validation , 2013 .

[27]  Adrian Mariampillai,et al.  Speckle variance detection of microvasculature using swept-source optical coherence tomography. , 2008, Optics letters.

[28]  G. Jemec,et al.  Optical coherence tomography in the diagnosis of basal cell carcinoma , 2014, Archives of Dermatological Research.