Hemodynamic Change In A Cerebral Aneurysm Treated By Double Stenting Technique

Rupture of cerebral aneurysms often causes subarachnoid hemorrhage which is a life-threatening condition with high mortality rates. Larger aneurysms are believed to be more likely to rupture and should therefore be treated. Recently, flow diverters (FDs) are widely used to treat large or wide neck aneurysms. However, it can be difficult to treat them by deployment of a single FD because of its insufficient flow disturbance. To overcome this problem, double stenting technique is sometimes applied with the aim to improve the effect of blood velocity reduction. In this study, we used computational fluid dynamics (CFD) to investigate the hemodynamic changes in an aneurysm when deploying virtual FDs. The results showed that the characteristics of the blood flow field inside the aneurysm did not changed much after the deployment of a single FD but underwent a large change after the deployment of two FDs. Furthermore, the velocity reduction in the aneurysm sac at a plane away from the parent artery increased from 25.9% to 92.8% when two FDs were deployed instead of one compared to no stenting. Double stenting was effective to decrease blood velocity in large or wide neck aneurysms.

[1]  Yiqian,et al.  Hemodynamic Differences Between Unruptured and Ruptured Intracranial Aneurysms During Observation , 2012 .

[2]  Aman B Patel,et al.  Guidelines for the Management of Aneurysmal Subarachnoid Hemorrhage: A Statement for Healthcare Professionals From a Special Writing Group of the Stroke Council, American Heart Association , 1994, Stroke.

[3]  D. Nichols,et al.  Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment , 2003, The Lancet.

[4]  V. Pereira,et al.  Flow diversion treatment: intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosis , 2012, Acta Neurochirurgica.

[5]  Adnan H Siddiqui,et al.  Computer modeling of deployment and mechanical expansion of neurovascular flow diverter in patient-specific intracranial aneurysms. , 2012, Journal of biomechanics.

[6]  P. Liu,et al.  Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review , 2016, The neuroradiology journal.

[7]  W. Thies,et al.  Guidelines for the management of aneurysmal subarachnoid hemorrhage. A statement for healthcare professionals from a special writing group of the Stroke Council, American Heart Association. , 1994, Stroke.

[8]  D. Holdsworth,et al.  Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries , 2005, Physiological measurement.

[9]  D. Ku,et al.  Fluid mechanics of vascular systems, diseases, and thrombosis. , 1999, Annual review of biomedical engineering.